Design Guide
90 
|
 Wolf Customer Care 800.222.7820
Planning Information
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on 
the following pages. A separate circuit, servicing only this 
appliance is required.
When multiple cooktops or modules are installed side by 
side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply grounded 3-wire, 240/208 VAC, 50/60 Hz
Steamer, Fryer, Grill 15 amp dedicated circuit
Teppanyaki 20 amp dedicated circuit
Conduit exible 4'
 (1.2 m)
GAS MULTIFUNCTION
Electrical Supply grounded, 120 VAC, 50/60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
 (1.8 m)
VENTILATION OUTDOOR GRILLS RANGES | RANGETOPS COOKTOPS | COFFEE BUILT-IN OVENS
INTEGRATED MODULES
GAS SUPPLY
Installation must comply with all applicable gas codes.
For the multifunction module, a gas supply line of 
3
/4" (19) 
rigid pipe must be provided to the module. If local codes 
permit, a certied, 3'
 (.9 m) long, 
1
/2" (13) or 
3
/4" (19) ID exible 
metal appliance connector is recommended to connect the 
units 
1
/2" NPT male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side 
by side, they can receive their gas supply from a common 
line. However, each unit must have its own regulator 
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
 in altitude without adjustment and LP gas cooktops 
will function up to 8,600'
 (2621 m). If the installation exceeds 
these elevations, contact an authorized Wolf dealer for a 
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)