Design Guide
wolfappliance.com 
|
 31
WOLF CONVECTION STEAM OVENS
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations 
on the following pages. A separate circuit, servicing only 
this appliance is required. A ground fault circuit interrupter 
(GFCI) is not recommended and may cause interruption of 
operation. Refer to the illustration below for minimum power 
cord plug clearance.
Performance may be compromised if the electrical supply is 
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 20 amp dedicated circuit
Receptacle NEMA 6-20R grounding-type
Power Cord 6'
 (1.8 m)
Planning Information
The convection steam oven can be installed in a standard 
or ush inset application. The electrical supply for the oven 
must be located in an adjacent cabinet.
Finish the edges of the opening. They may be visible when 
the door is open.
For standard installations, face trim will overlap stiles and 
rails. Refer to the chart below.
For ush inset installations, a minimum 
1
/8" (3) reveal is 
required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Convection Steam Oven 100 lb (45 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top
3
/16" (5)
3
/16" (5)
Bottom 0" (0) 0" (0)
Sides
11
/16" (18)  3
7
/8" (98)
3"
(76)
MINIMUM CORD
CLEARANCE
Power cord clearance.