Specifications
33
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF INTEGRATED MODULES
E
5" (127)
G
15"
(381)
15"
(381)
33" (838)
RECOMMENDED
CABINET WIDTH
LOCATION OF GAS SUPPLY
MAY ALSO EXTEND 5" ON
FLOOR FROM BACK WALL
5"
(127)
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 5" ON FLOOR
FROM BACK WALL
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
14" (356)
CUT-OUT
WIDTH
18"
(457)
7"**
(178)
18"
(457)
7"**
(178)
24" OR 30"*
(610 or 762)
TO COUNTERTOP
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
2
1
/2"**
(64)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) module. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected
cabinet to countertop. **Minimum clearance from side and rear edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
INSTALLATION SPECIFICATIONS
Gas Multi-Function Cooktop
Countertop Cut-Out Dimensions
SPECIFICATIONS
Gas Multi-Function Cooktop
Natural Gas Model IM15/S
LP Gas Model IM15/S-LP
Overall Width 15" (381)
Overall Height 5" (127)
Overall Depth 21" (533)
Burner Rating 18,000 Btu/hr
(5.3 kW)
Cabinet Depth 22
3
/4" (578) min
Height Clearance 5" (127) min
Cut-Out Width 14" (356)
Cut-Out Depth 19
1
/4" (489)
Electrical Supply 120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord 6' (1.8 m) 3-prong
Gas Rating 18,000 Btu/hr
(5.3 kW)
Shipping Weight 30 lbs (14 kg)
Dimensions may vary to
+
–
1
/
8
" (3).
PLANNING INFORMATION
The illustrations provide the overall dimensions
and finished cut-out dimensions that you need
to plan for in your installation.
IMPORTANT NOTE: When multiple cooktops
and/or modules are installed side by side, refer
to page 23 for countertop cut-out dimensions.
This cooktop module can accommodate a Wolf
downdraft system, a cooktop or Pro ventilation
hood. When installing a ventilation hood, refer
to the specific requirements of the hood for the
minimum dimension to the countertop. Refer
to pages 66–90 for ventilation specifications.
ELECTRICAL | GAS REQUIREMENTS
The electric ignition system is a safe, convenient
and reliable manner to provide ignition for the
burner. The Wolf gas multi-function cooktop
requires a separate 120 V AC, 60 Hz power supply.
FRONT OF COUNTERTOP
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
14" (356)
COOKTOP
CUT-OUT
WIDTH
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within reach of the power
cord. Locate electrical and gas supply within
the shaded area shown in the illustration.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
The gas multi-function cooktop is designed to
operate on natural gas at 5" WC pressure or LP
gas at 10" (254) WC pressure. The maximum
gas supply pressure to the regulator should
never exceed 14" (356) WC, .5 psi (3.5 kPa). It is
supplied with a
1
/2" NPT male gas connection at
the right rear corner of the module.
You must follow all National Electrical Code and
gas regulations. In addition, be aware of local
codes and ordinances when installing your
services.
HIGH ALTITUDE
The Wolf gas multi-
function cooktop
functions up to 8,000'
(2438 m) in altitude
without any adjust-
ment. If installation is
above 8,000' (2438
m), contact your Wolf
dealer.
INSTALLATION
Refer to the installation
instructions shipped with
each Wolf product for
detailed specifications.