Specifications
27
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF INTEGRATED MODULES
33" (838)
RECOMMENDED
CABINET WIDTH
E
6
1
/4"
(159)
15"
(381)
15"
(381)
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
14" (356)
CUT-OUT
WIDTH
18"
(457)
7"**
(178)
18"
(457)
7"**
(178)
24" OR 30"*
(610 or 762)
TO COUNTERTOP
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) module. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected
cabinet to countertop. **Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
INSTALLATION SPECIFICATIONS
Electric Grill Module
Countertop Cut-Out Dimensions
SPECIFICATIONS
Electric Grill Module
Overall Width 15" (381)
Overall Height 6
1
/4" (159)
Overall Depth 21" (533)
Temperature Zones Two
Heating Element 1400 W
Zone (front)
Heating Element 1400 W
Zone (rear)
Total Element Power 2800 W
Cabinet Depth 22
3
/4" (578) min
Height Clearance 6
1
/4" (159) min
Cut-Out Width 14" (356)
Cut-Out Depth 19
1
/4" (489)
Electrical Supply 240/208 V AC, 60 Hz
15 amp dedicated circuit
Conduit 4' (1.2 m) flexible 3-wire
Electrical Rating 2.8 kW at 240 V
2.1 kW at 208 V
Shipping Weight 50 lbs (28 kg)
Dimensions may vary to
+
–
1
/
8
" (3).
PLANNING INFORMATION
The illustrations provide the overall dimensions
and finished cut-out dimensions that you need
to plan for in your installation. We have mini-
mized the information contained in the illustra-
tions, concentrating on the critical information
you must plan into your installation.
IMPORTANT NOTE: When multiple cooktops
and/or modules are installed side by side, refer
to page 23 for countertop cut-out dimensions.
The grill module can accommodate a Wolf
cooktop or Pro ventilation hood. When installing
a ventilation hood, refer to the specific require-
ments of the hood for the minimum dimension
to the countertop. Refer to pages 66–90 for
ventilation specifications.
IMPORTANT NOTE: Wolf does not recommend
the use of downdraft ventilation with the electric
grill module.
FRONT OF COUNTERTOP
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
14" (356)
COOKTOP
CUT-OUT
WIDTH
ELECTRICAL REQUIREMENTS
The Wolf electric grill module requires a
separate, grounded 3-wire 240/208 V AC, 60 Hz,
15 amp service with its own circuit breaker.
Locate electrical within the shaded area shown
in the illustration.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
INSTALLATION
Refer to the
installation
instructions shipped
with each Wolf
product for detailed
specifications.