Specifications

25
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF INTEGRATED MODULES
E
13
3
/8" (340)
CUT-OUT
WIDTH
6"
(152)
FRONT OF COUNTERTOP
15"
(381)
15"
(381)
33" (838)
RECOMMENDED
CABINET WIDTH
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
13
3
/8" (340)
COOKTOP
CUT-OUT
WIDTH
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
24" OR 30"*
(610 or 762)
TO COUNTERTOP
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) module. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected
cabinet to countertop. **Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
INSTALLATION SPECIFICATIONS
Induction Cooktop
Countertop Cut-Out Dimensions
SPECIFICATIONS
Induction Cooktop
Overall Width 15" (381)
Overall Height 2
1
/2" (64)
Overall Depth 21" (533)
Heating Elements Two
Max Element Power 1800 W
(front)
Max Element Power 2200 W
(rear)
Cabinet Depth 22
3
/4" (578) min
Height Clearance 6" (152) min
Cut-Out Width* 13
3
/8" (340)
Cut-Out Depth 19
1
/4" (489)
Electrical Supply 240/208 V AC, 60 Hz
20 amp dedicated circuit
Conduit 4' (1.2 m) flexible 3-wire
Electrical Rating 3.4 kW at 240 V
2.6 kW at 208 V
Shipping Weight 30 lbs (14 kg)
*If the induction cooktop is to be used with
any combination of additional cooktop units or
modules with a filler strip, the cut-out width
increases to 14" (356).
IMPORTANT NOTE: A minimum height clearance
of 6" (152) is required. If a shelf is installed
below the unit, a 1" (25) gap at the rear of the
cabinet shelf is necessary to allow for proper
ventilation. Failure to do so could result in
decreased performance or product damage.
Dimensions may vary to
+
1
/
8
" (3).
PLANNING INFORMATION
The illustrations provide the overall dimensions
and finished cut-out dimensions that you need
to plan for in your installation. We have mini-
mized the information contained in the illustra-
tions, concentrating on the critical information
you must plan into your installation.
IMPORTANT NOTE: When multiple cooktops
and/or modules are installed side by side, refer
to page 23 for countertop cut-out dimensions.
This cooktop module can accommodate a Wolf
downdraft system, a cooktop or Pro ventilation
hood. When installing a ventilation hood, refer
to the specific requirements of the hood for the
minimum dimension to the countertop. Refer
to pages 6690 for ventilation specifications.
ELECTRICAL REQUIREMENTS
The Wolf induction cooktop requires a separate,
grounded 3-wire 240/208 V AC, 60 Hz, 20 amp
service with its own circuit breaker. Locate
electrical within the shaded area shown in the
illustration.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
INSTALLATION
Refer to the
installation
instructions shipped
with each Wolf
product for detailed
specifications.