Specifications
17
Dimensions in parentheses are in
millimeters unless otherwise specified.
39" (991)
RECOMMENDED CABINET WIDTH
SEE COUNTERTOP CUT-OUT BELOW
*Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop.
**Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
24" OR 30"*
(610 or 762)
TO COUNTERTOP
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
SEE COUNTERTOP
CUT-OUT BELOW
36-INCH OVEN OPENING
24"min
(610)
4" (102)
10"
(254)
3
1
/2" (89)
E
4"
min (102)
13" max
(330)
21"
(533)
OVERALL
DEPTH
36" (914)
OVERALL WIDTH
4" (102)
OVERALL DIMENSIONS
36" (914) Unframed Electric Cooktop
INSTALLATION SPECIFICATIONS
36" (914) Unframed Electric Cooktop
Countertop Cut-Out Dimensions
WOLF ELECTRIC COOKTOPS
SPECIFICATIONS
36" (914) Unframed Electric Cooktop
Overall Width 36" (914)
Overall Height 4" (102)
Overall Depth 21" (533)
Heating Elements Five
Temperature Zones Eight
Max Element Power 1050 W / 2200 W /
(triple) 2700 W
Max Element Power 750 W / 2200 W
(dual)
Max Element Power 1200 W, 1500 W
(three single) and 1800 W
Cabinet Width 39" (991) rec
Cabinet Depth 22
3
/4" (578) min
Height Clearance 4" (102) min
Cut-Out Width 34
3
/8" (873)
Cut-Out Depth 19
3
/8" (492)
Electrical Supply 240 V AC / 60 Hz / 50 amp
208 V AC / 60 Hz / 40 amp
Conduit 4' (1.2 m) flexible 3-wire
Electrical Rating 9.4 kW at 240 V
7.1 kW at 208 V
Shipping Weight 60 lbs (27 kg)
INSTALLATION OPTIONS
The Wolf 36" (914) unframed electric cooktop
can be mounted flush with the top of the
countertop or as a frameless installation
sitting on top of the countertop surface. In
either installation the cooktop cut-out dimen-
sions are the same. If mounted flush with
the countertop, a recessed area surrounding
the cooktop cut-out is required.
IMPORTANT NOTE: Flush mount installations
are intended for granite, solid surface or
stone countertop surfaces only. If the
cooktop is to be mounted flush with the
countertop, fabrication of the recessed area
must take place before the final countertop
installation. A template of the countertop
cut-out will be provided with the cooktop for
fabrication purposes.
A Wolf 36" (914) single oven may be installed
below the 36" (914) unframed electric
cooktop. For this installation, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply
be placed in the base cabinet to the right of
the oven. A Wolf 30" (762) single oven may
also be installed below the Wolf 36" (914)
unframed electric cooktop. Refer to pages
6 and 7 for additional specifications.
When a 36" (914) oven is installed below a
cooktop, it is recommended that the rough
opening for the oven be 7
3
/4" (197) from the
floor to ease the use of the oven door.
36
1
/8"* (918)
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
34
3
/8" (873)
COOKTOP CUT-OUT WIDTH
1
5
/16" (49)
RADIUS
FRONT OF COUNTERTOP
2
7
/16" (62)
19
3
/8" (492)
COOKTOP
CUT-OUT DEPTH
1
9
/16" (40)
21
1
/8"* (537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
7
/16" (11) RADIUS
*Minimum dimension, but may be exceeded by up to
1
/
8
" (3).
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
5
/16"
(
24
)
7
/8"
(22) max
COUNTERTOP
PROFILE
Dimensions may vary to
+
–