Specifications

16
33" (838)
RECOMMENDED
CABINET WIDTH
30-INCH OVEN OPENING
*Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop.
**Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
24" OR 30"*
(610 or 762)
TO COUNTERTOP
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
36"(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
SEE COUNTERTOP
CUT-OUT BELOW
SEE COUNTERTOP
CUT-OUT BELOW
4" (102)
10"
(254)
3
1
/2" (89)
E
24"min
(610)
4"min (102)
13" max
(330)
21"
(533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
4" (102)
Countertop Cut-Out Dimensions
OVERALL DIMENSIONS
30" (762) Unframed Electric Cooktop
INSTALLATION SPECIFICATIONS
30" (762) Unframed Electric Cooktop
SPECIFICATIONS
30" (762) Unframed Electric Cooktop
Overall Width 30" (762)
Overall Height 4" (102)
Overall Depth 21" (533)
Heating Elements Four
Temperature Zones Six
Max Element Power 750 W / 2200 W and
(two dual) 950 W / 1900 W
Max Element Power 1200 W and 1500 W
(two single)
Cabinet Width 33" (838) rec
Cabinet Depth 22
3
/4" (578) min
Height Clearance 4" (102) min
Cut-Out Width 28
3
/8" (721)
Cut-Out Depth 19
3
/8" (492)
Electrical Supply 240 V AC / 60 Hz / 40 amp
208 V AC / 60 Hz / 30 amp
Conduit 4' (1.2 m) flexible 3-wire
Electrical Rating 6.8 kW at 240 V
5.2 kW at 208 V
Shipping Weight 45 lbs (20 kg)
WOLF ELECTRIC COOKTOPS
INSTALLATION OPTIONS
The Wolf 30" (762) unframed electric cooktop
can be mounted flush with the top of the
countertop or as a frameless installation
sitting on top of the countertop surface. In
either installation the cooktop cut-out dimen-
sions are the same. If mounted flush with
the countertop, a recessed area surrounding
the cooktop cut-out is required.
IMPORTANT NOTE: Flush mount installations
are intended for granite, solid surface or
stone countertop surfaces only. If the
cooktop is to be mounted flush with the
countertop, fabrication of the recessed area
must take place before the final countertop
installation. A template of the countertop
cut-out will be provided with the cooktop for
fabrication purposes.
A Wolf 30" (762) single oven may be installed
below the 30" (762) unframed electric
cooktop. For this installation, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply
be placed in the base cabinet to the right of
the oven. Refer to page 6 for additional
specifications.
28
3
/8" (721) COOKTOP
CUT-OUT WIDTH
1
5
/16" (49)
RADIUS
2
7
/16" (62)
19
3
/8" (492)
COOKTOP
CUT-OUT DEPTH
7
/16" (11) RADIUS
30
1
/8"*
(
765
)
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
FRONT OF COUNTERTOP
1
9
/16" (40)
21
1
/8"* (537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
*Minimum dimension, but may be exceeded by up to
1
/8" (3).
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
5
/16"
(
24
)
7
/8"
(22) max
COUNTERTOP
PROFILE
Dimensions may vary to
+
1
/