C OOKTOP L OW-P ROFILE H OODS I NSTALLATION I NSTRUCTIONS
C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions.
W O L F C O O K TO P L OW- P R O F I L E H O O D S I N S TA L L AT I O N R E Q U I R E M E N T S B E F O R E YO U S TA RT IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. IMPORTANT NOTE: Wolf cooktop low-profile hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. For ranges and rangetops, a Wolf Pro ventilation hood is recommended.
W O L F C O O K TO P L OW- P R O F I L E H O O D S WA L L H O O D S 9 7/8" 10 7/8" (251) (276) MODEL CTEWH30I 5 7/8" (149) TO 18 3/8" (467) 29 1/8" (740) Overall Width 30" (762) Height (excluding chimney) 3 1/8" (79) Min Height (including chimney) TO 411/2" (1054) OVERALL HEIGHT 20 1/8" (511) Max Height (full extension) 29 1/8" (740) 41 1/2" (1054) 17 3/4" (451) Overall Depth Shipping Weight 53 lbs (24 kg) 3 1/8" (79) 17 3/4" 30" (762) (451) OVERALL DEPTH OVERALL WIDTH MODEL CTEWH36(I)
I N S TA L L AT I O N I N S T R U C T I O N S ISLAND H O O D MODEL CTEIH42I Overall Width Height (excluding chimney) Min Height (including chimney) 42" (1067) 12 1/8" 10 7/8" (308) (276) 2 1/8" (54) TO 3 1/8" (79) 15 1/2" (394) 28 1/4" (718) 28 1/4" (718) 41 1/2" (1054) 411/2" (1054) TO Max Height (full extension) Overall Depth Shipping Weight 22 7/8" OVERALL HEIGHT 21 5/8" (549) (581) 92 lbs (42 kg) 3 1/8" (79) Dimensions may vary to –+ 1/8" (3).
W O L F C O O K TO P L OW- P R O F I L E H O O D S I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. ELECTRICAL R E Q U I R E M E N T S I N S TA L L AT I O N O P T I O N S You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
I N S TA L L AT I O N I N S T R U C T I O N S D U C T E D I N S TA L L AT I O N IMPORTANT NOTE: There is a possibility of noise issues, when using a remote blower with a short duct run. WA L L A N D I S L A N D H O O D S To reduce the risk of fire, use only metal ductwork. IMPORTANT NOTE: Consult a qualified HVAC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood to perform more efficiently.
W O L F C O O K TO P L OW- P R O F I L E H O O D S WA L L H O O D S – D U C T E D IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Locate the electrical supply through the wall within the shaded area shown in illus 1. Install ductwork as outlined on page 7. If an optional backsplash is to be used, attach it to the finished wall. Secure the hood mounting brackets to the wall studs prior to installing the backsplash.
I N S TA L L AT I O N I N S T R U C T I O N S WA L L H O O D S – D U C T E D FIXING THE TELESCOPIC FLUE WIRING Adjust the width of the support bracket (D) of the telescopic flue by means of the screws (E) as shown in illus 5. Then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned along the axis with your hood. IMPORTANT NOTE: The ventilation hood must be properly grounded.
W O L F C O O K TO P L OW- P R O F I L E H O O D S WA L L H O O D S – D U C T E D I N - L I N E O R R E M OT E B L OW E R Blower connection at hood: Follow the installation steps for wall hoods on pages 8–9. Additional wiring connections must be made for the in-line or remote blower. Installation instructions will be provided with the remote blower. 1) Run conductors (2-wire plus ground) from the in-line or remote blower to the hood's wiring box marked "motor connection".
I N S TA L L AT I O N I N S T R U C T I O N S WA L L H O O D S – R E C I R C U L A T I N G IMPORTANT NOTE: The recirculation kit must be purchased separately for recirculating installations. IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Locate the electrical supply through the wall and inside the area of the flue, above the mounting bracket and right of center.
W O L F C O O K TO P L OW- P R O F I L E H O O D S ISLAND HOODS – D U C T E D IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Locate the electrical supply through the ceiling inside the area of the flue. Install ductwork as outlined on page 7. F I X I N G TO T H E C E I L I N G Mount the metal panel with four screws as shown in illus 15.
I N S TA L L AT I O N I N S T R U C T I O N S ISLAND HOODS – D U C T E D Adjust the height of the telescopic flue by means of the four retaining screws (C) shown in illus 20. Take into account that the height of the hood is 31/8" (79) and the bottom of the hood should be a minimum of 24" (610) and a maximum of 30" (762) above the countertop. Take the upper flue (with the round slots) and slide it on the telescopic flue with the slots facing upwards.
W O L F C O O K TO P L OW- P R O F I L E H O O D S I S L A N D H O O D S – R E C I R C U L AT I N G IMPORTANT NOTE: The recirculation kit must be purchased separately for recirculating installations. IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Locate the electrical supply through the ceiling inside the area of the flue.
I N S TA L L AT I O N I N S T R U C T I O N S I S L A N D H O O D S – R E C I R C U L AT I N G Raise the hood to the telescopic flue and connect the air outlet duct to the reduction. Attach the hood to the telescopic flue by means of four screws (provided) as shown in illus 28. WIRING Follow the same wiring connections as outlined on page 13. ACCESSORIES F I T T I N G T H E C H A R C O A L F I LT E R Optional accessories are available through your Wolf dealer.
W O L F C O O K TO P L OW- P R O F I L E H O O D S I N - L I N E A N D R E M OT E B L O W E R S IMPORTANT NOTE: For mounting and installation of an in-line or remote blower, refer to the specific installation instructions provided with each blower. Locate the in-line or remote blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. Wolf recommends the maximum linear duct run be no greater than 50' (15 m).
I N S TA L L AT I O N I N S T R U C T I O N S I N - L I N E A N D R E M OT E B L O W E R S Refer to the illustrations below for overall dimensions of Wolf remote blowers.
W O L F C O O K TO P L OW- P R O F I L E H O O D S I N - L I N E A N D R E M OT E B L O W E R S IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is in the OFF position. BLOWER WIRING I M P O R TA N T N OT E You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. 1) Remove the cover from the front of the electrical box.
I N S TA L L AT I O N I N S T R U C T I O N S TROUBLES H O OT I N G I F Y O U N E E D S E RV I C E IMPORTANT NOTE: If the cooktop low-profile hood does not operate properly, follow these troubleshooting steps: Maintain the quality built into your cooktop low-profile hood by calling a Wolf authorized service center. Verify that power is being supplied to the ventilation hood.
WOLF APPLIANCE, INC. 812508 / 04308006 5 / 2008 P. O . B O X 4 4 8 4 8 MADISON, WI 53744 800-332-9513 W O L FA P P L I A N C E .