INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods
Contents Important Note Wolf Cooktop Low-Profile Ventilation Hoods . . . . . . . . 3 To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: Cooktop Low-Profile Hood Specifications . . . . . . . . . . 4 Cooktop Low-Profile Hood Installation . . . . . . . . . . . . 8 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wolf Cooktop Low-Profile Ventilation Hoods 3 wolfappliance.com/specs Cooktop Low-Profile Hood Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
Cooktop Low-Profile Hood Specifications 4 Overall Dimensions LOW-PROFILE WALL HOODS 9 7/8" 10 7/8" 10 7/8" (251) (276) (276) 5 7/8" (149) 7 7/8" (200) TO 18 3/8" (467) 25 1/2" (648) 29 1/8" (740) TO 31" (788) TO TO 20 1/8" (511) 411/2" (1054) 20 1/8" (511) 48 3/4" (1238) 3 1/8" (79) 30" (762), 36" (914) AND 45" (1143) WIDTHS 3 1/8" (79) 17 3/4" 17 3/4" (451) (451) RECIRCULATING APPLICATION LOW-PROFILE ISLAND HOOD 11 3/4" 9 7/8" (298) (251) 9 7/8" (251) 2 3/8" (60) 4 3/4" (1
Cooktop Low-Profile Hood Specifications 5 wolfappliance.com/specs Installation Considerations Electrical Requirements Wolf cooktop low-profile hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. These hoods have a telescopic flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. Wolf cooktop low-profile ventilation hoods require a separate, grounded 120 V AC, 60 Hz power supply.
Cooktop Low-Profile Hood Specifications 6 Installation Specifications LOW-PROFILE WALL HOODS 291/8" (740) TO 411/2" (1054) HEIGHT OF HOOD E LOCATION OF ELECTRICAL 5" (127) 15" (381) 17 3/4" (451) DEPTH OF HOOD 30" (762), 36" (914) OR 45" (1143) 8' (2.4 m) TO 9' (2.
Cooktop Low-Profile Hood Specifications 7 wolfappliance.com/specs Installation Specifications LOW-PROFILE ISLAND HOODS LOCATION OF ELECTRICAL THROUGH TOP OF HOOD 28 1/4" (718) TO 411/2" (1054) HEIGHT OF HOOD 21 5/8" (549) DEPTH OF HOOD 42" (1067) WIDTH OF HOOD 8' (2.4 m) TO 9' (2.
Cooktop Low-Profile Hood Installation Ducting Options Wolf cooktop low-profile hoods may be used in a ducted or recirculating installation. For greatest efficiency, the ducted installation is recommended. DUCTED INSTALLATION In a ducted installation, the hood aspirates the kitchen air saturated with fumes and odors, passes it through the grease filter and expels it to the outside through ductwork. For this installation, a ventilation hood with an internal, in-line or remote blower can be used.
Cooktop Low-Profile Hood Installation 9 wolfappliance.com/specs Install Ductwork LOW-PROFILE WALL HOODS LOW-PROFILE ISLAND HOOD DUCTWORK INSTALLATION THROUGH ROOF DUCTWORK INSTALLATION THROUGH ROOF 10 7/8" (276) 8' (2.4 m) TO 9' (2.
Cooktop Low-Profile Hood Installation 10 Wall Hoods—Ducted Installation Locate the electrical supply through the wall within the shaded area shown in the illustration on page 6. Install ductwork as outlined on pages 8–9. Mount the bottom panel to the hood. Attach with the four screws provided on the hinge side of the panel. IMPORTANT NOTE: If a backsplash is to be used, it should be installed prior to mounting the wall hood.
Cooktop Low-Profile Hood Installation 11 wolfappliance.com/specs Wall Hoods—Ducted Installation Fit 6" (152) flexible metal ducting (not provided) to the air vent of the hood and seal with duct tape. Refer to illus 5 below. For exhaust hoods, turn the upper flue over so that the air exhaust grid is in the lower section. IN-LINE OR REMOTE BLOWER WIRING Blower connection at the hood: 1) Run Romex® wire from the in-line or remote blower to the hood’s electrical box marked “motor connection”.
Cooktop Low-Profile Hood Installation 12 Wall Hoods—Recirculating Installation INTERNAL BLOWER MODELS WIRING CONNECTIONS IMPORTANT NOTE: A recirculation kit is required for this installation. The kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Follow the same instructions for wiring connections as outlined for ducted installations on page 11.
Cooktop Low-Profile Hood Installation 13 wolfappliance.com/specs Island Hoods—Ducted Installation Locate the electrical supply through the wall within the shaded area shown in the illustration on page 7. Install ductwork as outlined on pages 8–9. Mount the bottom panel to the hood. Attach with the four screws provided on the hinge side of the panel. Refer to illus 12 below.
Cooktop Low-Profile Hood Installation 14 Island Hoods—Ducted Installation ATTACH TELESCOPIC FLUE WIRING CONNECTIONS Attach the telescopic flue to the mounting bracket with four screws provided. Run the air evacuation pipe through the telescopic flue and run the Romex® wire through the hole in the bracket. Adjust the height of the telescopic flue with the four retaining screws. Refer to illus 15 below.
Cooktop Low-Profile Hood Installation 15 wolfappliance.com/specs Island Hoods—Recirculating Installation IMPORTANT NOTE: A recirculation kit is required for this installation. The kit is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Attach the reduction to the air venting opening of the hood by pressing slightly. Refer to illus 21 below.
Cooktop Low-Profile Hood Installation 16 Island Hoods—Recirculating Installation INSTALL CHARCOAL FILTER First remove the grease filters. To access the filters, gently press up on the front edge of the bottom panel and allow it to rotate downward. Push the handle outward and pull the grease filters downward to remove. Then install the charcoal filter by inserting the two filter clips in the slots and turning the filter towards the inside of the hood.
Cooktop Low-Profile Hood Installation 17 wolfappliance.com/specs In-Line and Remote Blowers Allow enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instructions provided with each blower assembly for additional mounting and wiring instructions. Refer to the illustrations below for overall dimensions of Wolf in-line and remote blowers.
Service Information 18 Troubleshooting Service Information IMPORTANT NOTE: If the ventilation hood does not operate properly, follow these troubleshooting steps: If service is necessary, maintain the quality built into your ventilation hood by calling a Wolf authorized service center. • Verify that electrical power is being supplied to the ventilation hood. • Check electrical connections to ensure that the installation has been completed correctly.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 816999 REV-A 8/ 2010 WOLFAPPLIANCE.COM 800.332.