I NDUCTION C OOKTOP I NSTALLATION I NSTRUCTIONS
C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions.
W O L F I N D U C T I O N C O O K TO P S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: Save these Installation Instructions for the local inspector’s use. Please read the entire Installation Instructions prior to installation. This installation must be completed by a qualified technician. Installer: please retain these instructions for local inspector’s reference, then leave them with the homeowner.
W O L F I N D U C T I O N C O O K TO P S S I T E P R E PA R AT I O N IMPORTANT NOTE: Installation of the Wolf induction cooktop must meet the following location requirements. All dimensions listed are minimum requirements for safe operation. Refer to the illustration below. To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided.
I N S TA L L AT I O N I N S T R U C T I O N S I N S TA L L AT I O N S P E C I F I C A T I O N S The illustrations on pages 6–8 provide the overall dimensions, installation specifications and countertop cut-out for each of the Wolf induction cooktop models. These cooktops are designed to fit a standard 24" (610) deep base cabinet with a 25" (635) deep countertop. Before making the countertop cut-out, verify that the cooktop will clear the side walls of the base cabinet below.
W O L F I N D U C T I O N C O O K TO P S M O D E L CT15I/S The illustrations below provide installation specifications for Model CT15I/S. If Model CT15I/S is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 4' (1.2 m) of the right rear of the cooktop.
I N S TA L L AT I O N I N S T R U C T I O N S M O D E L CT30I/S The illustrations below provide installation specifications for Model CT30I/S. Refer to installation instructions provided with the built-in oven for additional specifications. For ease of installation, 33" (838) cabinets are recommended for installation of Model CT30I/S. If Model CT30I/S is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 4' (1.
W O L F I N D U C T I O N C O O K TO P S M O D E L CT36I/S The illustrations below provide installation specifications for Model CT36I/S. Refer to installation instructions provided with the built-in oven for additional specifications. For ease of installation, 39" (991) cabinets are recommended for installation of Model CT36I/S. If Model CT36I/S is installed above cabinets, the electrical placement is not critical. A grounded electrical box should be located within 4' (1.
I N S TA L L AT I O N I N S T R U C T I O N S M U LT I P L E C O O K TO P I N S TA L L A T I O N If the induction cooktop is to be used with any combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the corresponding units' cut-out dimensions plus 1 1/4" (32) for each additional unit. Refer to the illustration below.
W O L F I N D U C T I O N C O O K TO P S ELECTRICAL R E Q U I R E M E N T S Verify that power is disconnected from the electrical box before proceeding. I M P O R TA N T N OT E This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes.
I N S TA L L AT I O N I N S T R U C T I O N S ELECTRICAL R E Q U I R E M E N T S This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse.
W O L F I N D U C T I O N C O O K TO P S C O O K T O P I N S TA L L AT I O N B E F O R E O P E R AT I N G Attach the foam strip to the underside of the cooktop frame. Refer to the illustration below. Clean the ceramic glass surface carefully using the Cooktop Cleaning Crème provided with the cooktop. Remove all cleaning residue. Gently lower the cooktop into the cut-out area in the countertop and center. Check that the front edge of the cooktop is parallel to the front edge of the countertop.
I N S TA L L AT I O N I N S T R U C T I O N S V E N T I L AT I O N O P T I O N S IMPORTANT NOTE: It is recommended that you operate the Wolf induction cooktop with either a Wolf cooktop ventilation hood, downdraft system or Pro ventilation hood. Contact your Wolf dealer for details. Cooktop Wall Hood – 30" (762) or 36" (914) widths in classic stainless steel. Cooktop Island Hood – 42" (1067) width in classic stainless steel.
W O L F I N D U C T I O N C O O K TO P S TROUBLES H O OT I N G I F C O O K T O P D O E S N O T O P E R AT E IMPORTANT NOTE: If the induction cooktop does not operate properly, follow these troubleshooting steps: Verify that power is being supplied to the cooktop. Check electrical connections to ensure that the installation has been completed correctly. Follow troubleshooting procedures as described in the Wolf Induction Cooktops Use & Care Information.
I N S TA L L AT I O N I N S T R U C T I O N S I F Y O U N E E D S E RV I C E If service is necessary, maintain the quality built into your induction cooktop by calling a Wolf authorized service center. To obtain the name and number of a Wolf authorized service center, check the Locator section of our website, wolfappliance.com or call Wolf Customer Service at 800-332-9513. When calling for service, you will need the cooktop model and serial numbers.
W O L F A P P L I A N C E C O M PA N Y, I N C. 809617 5 / 2007 P. O. B OX 4 4 8 4 8 MADISON, WI 53744 800-332-9513 W O L FA P P L I A N C E .