Design Guide
wolfappliance.com
|
83
BUILT-IN OVENS COOKTOPS | COFFEE RANGES | RANGETOPS OUTDOOR GRILLS VENTILATION
MODULE COOKTOPS
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use
of downdraft ventilation with the steamer, fryer, or grill
modules.
A minimum 2"
(51) is required from the bottom of the module
to combustible materials. For the teppanyaki module, a
minimum
7
/8" (22) is required from the bottom of the unit to
any material.
Refer to the illustrations on the following pages for installa-
tion of modules.
MULTIPLE COOKTOPS
When multiple cooktops or modules are installed side by
side, refer to the chart and illustration below for typical
congurations. The cutout dimensions provided will accom-
modate the use of an optional ller strip if desired.
For specic multiple cooktop and module conguration
options or the installation of more than six modules, contact
Wolf Customer Care at 800-222-7820.
COUNTERTOP CUTOUT
W
(2) 15" Modules* 29" (737)
(3) 15" Modules* 44" (1118)
(4) 15" Modules* 59
1
/4" (1505)
(5) 15" Modules* 74
1
/4" (1886)
(6) 15" Modules* 89
1
/4" (2267)
24" Cooktop**/15" Module* 37
5
/8" (956)
30" Cooktop/15" Module* 44" (1118)
30" Cooktop/(2) 15" Modules* 59" (1473)
36" Cooktop/15" Module* 50" (1270)
*Dimensions apply to CI152TF/S, CE152TF/S, CG152TF/S, SM15TF/S,
FM15TF/S, GM15TF/S, TM15TF/S and MM15TF/S.
**23
5
/8" actual product width.
2
1
/2"
(64) min
2
1
/2"
(64) min
19
1
/2"
(495)
CUTOUT
DEPTH
W
CUTOUT
WIDTH
FRONT OF COUNTERTOP
Countertop cutout