MODEL: AHP 
COUNTER MODEL ACHIEVER HOTPLATE
INSTALLATION REQUIREMENTS:
1.  A gas pressure regulator sized for this unit is included. Natural 
Gas 5.0" W.C. Propane Gas 10.0" W.C.
2.  An adequate ventilation system is required for commercial 
cooking equipment. Information may be obtained by writing 
to the National Fire Protection Association, 1 Batterymarch 
Park, Quicy, MA 02169, www.NFPA.org. When writing refer 
to NFPA No. 96.
3.  These units are manufactured for installation in accordance 
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 
        OVERALL  WORKING  NO. OF  TOTAL  APPROX. SHIP
  MODEL  WIDTH  DEPTH  HEIGHT  HEIGHT  BURNERS  BTU/HR.  WT. (LB/KG)
  AHP212  12"        2  60,000  95 lbs./43 kg
  AHP424  24"        4  120,000  165 lbs./74 kg
  AHP636  36" 
33"  14-5/8"  12-3/8"
  6  180,000  265 lbs./119 kg
  AHP848  48"        8  240,000  310 lbs./140 kg
Gas  Association,  Accredited  Standards  Committee  Z223 
@  400N.  Capital  St.  NW,  Washington, DC  20001, or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.
  NOTE: In the Commonwealth of Massachusetts
  All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped  with a damper  or with a  power 
means of exhaust shall comply with 248 CMR.
4.  This appliance must be installed with a 6" clearance at both 
sides and the rear adjacent to combustible construction.