Design Guide
wolfappliance.com | 115
Planning Information
When installing against a combustible surface, a minimum
10"
(254) riser is required for a 36" dual fuel range with
charbroiler or griddle and all 48" and 60" models. Follow all
minimum clearances to combustible surfaces shown in the
illustration on the following page.
A Wolf pro ventilation hood is recommended with the dual
fuel range. Refer to page 166 for Pro Ventilation.
DUAL FUEL RANGES
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the wall or oor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is being used with models that
require a 50 amp breaker, the cord must be designated for
use with ranges and rated for 240/208, 50 amps and must
include 3 or 4 conductors. A 4-conductor cord is required
for installations where grounding through the neutral is
prohibited.
Wolf dual fuel ranges have a terminal block that allows for a
3-wire or 4-wire installation.
ELECTRICAL REQUIREMENTS
SINGLE OVEN RANGE
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Total Amps 21
DOUBLE OVEN RANGE
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Total Amps 42.5