RM-2440 User Manual P/N 821574 Rev-C Section 1: General Features and Specifications
Installation
Unpacking
Unpack the RM-2440 unit from the shipping container and inspect all articles for shipping damage. If you find any damage,
notify the shipping carrier immediately for claims adjustments. Compare the shipping box contents to the packing slip. Contact
our PANORAMAdtv sales representative if there are any unexplained shortages.
Cooling and Airflow
No special physical mounting considerations are necessary regarding unit heat dissipation except under adverse conditions. Provided
the ambient temperature inside the mounting enclosure does not exceed 40 degrees Celsius (104 degrees Fahrenheit), adjacent devices
can be rack mounted (or stacked) in proximity to the RM-2440 unit. If the above temperature is exceeded, allow a 1RU (1.75”/25mm)
space above and below the unit for air circulation.
Rack Mounting
The RM-2440 unit rack mounts in a standard EIA-310-D specification 19”/483 mm rack and needs only 2RU of space. Allow
sufficient space at the unit rear for connector and cable clearance (approximately 4”/102mm). The RM-2440 unit rack
mounts from the front panel support rails. Rear support is not required.
See Figure-2c on page 12 for RM-2440 rack, standard connector, and optional RMSDI module connector clearance
dimensions.
General Installation Recommendations
Recommended Cables: Recommended cable type for Composite (analog) or SDI video signals is: Belden 1694A (or
equivalent).