The System Menu sets up basic operational parameters for each
MPEG-3270 or MPEG-4290 screen. This menu is shown in Figure 4–10.
Figure 4–10 System Menu
Rotate the Volume knob to highlight the item to be adjusted, and then
press to enter it. Again rotate the Volume knob to the option selection
and press to choose it:
1. BNC Port A: Using this option, you must designate whether the
type of signaling to the Port A BNC connector on the back panel is
SDI or ASI. By default, SDI is chosen.
2. BNC Port B: Using this option, you must designate whether the
type of signaling to the Port B BNC connector on the back panel is
SDI or ASI. By default, SDI is chosen.
3. Backlight Interval: To preserve the life of the LCD backlight on
each screen, a time-out is provided. This interval can be set to
None, which leaves and backlight on all of the time, or to one of 5
time intervals. By default, 8 hours is chosen.
4. Panel LEDs: In certain environments, the Power LED and other
status LEDs can be distracting. The LEDs on the front panel can be
dimmed (Refer to Panel LEDs, Item 9 on page 27 in the Adjust
Settings section.) or they can be turned off. This option allows the
Panel LEDs to be Off while the MPEG-3270 or MPEG-4290 is in
operation. The default setting is On, which causes the Panel LEDs
BNC Port B
System Menu
Backlight Interval
Panel LEDs
Calibration
Upgrade
None 5m 4h 8h 24h 48h
Restore
Upgrade
SDI ASI
Off On
BNC Port A SDI ASI