key must be purchased to enable this function. A software license must be
installed for SFP ports to function. Refer to the System Setup section in
Chapter 4 and to Figure 4-7 to install software licenses.
7. AES Inputs: (optional) This HD-15F connector accepts 4 AES3id digital
audio pairs (8 channels) at a 48 kHz sample rate. Refer to Figure 2-3 for
the pinout of this connector. The easiest way to interface with this
connector is to use an HD-15 to VGA adaptor cable. Channels are selected
as AES 1-8. A software license must be installed for these inputs to
function. Refer to the System Setup section in Chapter 4 and to Figure
4-7 to install software licenses.
Figure 2-3: AES HD-15F Connector Pinout
8. AES Outputs: This HD-15F connector provides 4 AES3id digital audio
pairs (8 channels) at a 48 kHz sample rate from selected monitored
sources. Refer to Figure 2-3 for the pinout of this connector. The easiest
way to interface with this connector is to use an HD-15 to VGA adaptor
cable. These outputs are not controlled by the Volume and Balance
controls. Monitored channels 1 and 2 are sent from AES-1, channels 3 and
4 are sent from AES-2, channels 5 and 6 are sent from AES-3, and
channels 7 and 8 are sent from AES-4.
9. SFP Module Cage: An SFP cage is provided to accept one optional SFP
module compatible with SDI coaxial or optical signals. The SFP modules
are hot swappable for convenience. An optional license key must be
purchased to enable each module. A software license must be installed for
the SFP port to function. Refer to the System Setup section in Chapter 4
and to Figure 4-7 to install software licenses. The following SFP modules
are offered:
a. 3G/HD/SD-SDI Single Video Receiver with Active Loopback:
This uses HD-BNC connectors.
b. 3G/HD/SD-SDI Video SFP with Optical Input: This uses LC
fiber connectors. It is a Single-Mode Receiver, Medium Haul, Non-
MSA, and no output.
c. SMTPE 2022-6 Receiver: This uses Multi-Mode 850 NM, LC fiber
connectors. It allows the iVAM1-1 to monitor SDI audio
transmitted in real time over Ethernet. You must use the emSET