Technical data
FLUE GAS ANALYSIS | WÖHLER A 600
FEATURES AND BENEFITS
· Wireless probe for versatile applications
· Core temperature search with displayed graph
· Rapid Readout Technology (R.R.T.)
RELIABILITY / SAFETY
· Full automatic calibration
· Automatic CO-safety-valve
· Self-monitoring filter and pump
· Enhanced self diagnosis
· Field replaceable sensors
· 6 filter technology
· More than 10 hours operation time with standard AA
rechargeable batteries
· Optional use of non-rechargeable standard AA batteries
VARIETY OF APPLICATIONS
· Multiple fuels: oil, gas and solid fuel fired heat appliances
· Sensors: O
2
, CO, NO, NO
2
, SO
2
, H
2
· Variety of probes for different measurement tasks
· Adapters for temperature and air flow probes
· Optional peltier-cooler and solid fuel adapter
· Customer adjustable fuel parameters
TÜV-APPROVED
· EN 50379 Part 2
· TÜV By RgG 248 according to EN 50379
DATA MANAGEMENT
· For more than 1,000 measurement records
· Infrared printer port
· Bluetooth link to computer or laptop
· USB interface
TECHNICAL DATA
Oxygen Concentration (O
²
)
Range .................................. 0…21.0 Vol.-%
Accuracy .............................. ± 0.3 Vol.-%
Carbon Monoxide Concentration (CO
low
), H
2
compensated
Range .................................. 0…4,000 Vol.-ppm
Accuracy .............................. ± 20 ppm: (< 400 ppm), otherwise 5 % of reading
Hydrogen Concentration (H
2
)
Range .................................. 0…1,000 Vol.-ppm
Accuracy .............................. ± 40 ppm (<400 ppm), otherwise 10 % of reading
NO-measurement (optional)
Range .................................. 0...2,000 ppm
Accuracy .............................. ± 5 ppm (<400 ppm), otherwise 5 % of reading
NO
2
-measurement (optional)
Range .................................. 0...150 ppm
Accuracy .............................. ± 2 ppm within the range up to 40 ppm, otherwise ± 5 % o.r.
SO
2
-measurement (optional)
Range .................................. 0...4,000 ppm
Accuracy .............................. ± 10 within the range up to 200 ppm, otherwise ±5 % o.r.
Carbon Monoxide Concentration (CO
high
) (opt)
Range .................................. 0…100,000 Vol.-ppm
Accuracy .............................. ± 100 Vol.-ppm (<1,000 ppm),10 % of reading
Nitrogen Concentration (NO) (opt)
Range .................................. 0…2,000 Vol.-ppm, (permanent up to 1,000 ppm)
Accuracy .............................. ± 5 ppm (< 400 ppm), otherwise 5 % of reading
Draft/Differential Pressure (PD)
Range .................................. ± 150 hPa
Accuracy .............................. ± 3.0 Pa (< 100,0 Pa), otherwise 3 % of reading
Resolution ............................ 0.1 Pa
Air temperature (T
A
)
Range .................................. -20.0…100.0 °C
Accuracy .............................. ± 1 °C
Flue Gas temperature (T
S
)
Range .................................. -10.0…900.0 °C
Accuracy .............................. EN 50379, Part 2
CO
²
-Calculation
Range .................................. 0…CO
2max
Resolution ............................ 0,1 %
Stack losses Q
A
in reference to the selected fuel (Siegert formula)
Efficiency
Range .................................. 0…100.0 % condensation is automatically detected
Accuracy .............................. 0.1 %
Dew point temperature
in reference to selected fuel
Resolution ............................ 0.1 °C
Condensate ........................ readings in kg/m3 (gas) or kg/l (Öl)
Air speed ............................approx. 130 m/s
Resolution ............................ < 0.4 m/s
Air flow ..............................0...2,000 m
3
/h
Resolution ............................ approx. 1 m
3
/h
Date/time ...........................realtime clock with backup battery
Storage temperature .........-20…50 °C
Work temperature .............5…40 °C to meet specifications
Battery hand held ..............6 x AA rechargeable batteries or mains supply
Battery wireless probe ...... 3 x AA rechargeable batteries or mains supply
Weight ................................ approx. 1,200 g
Size ....................................240 x 155 x 65 mm (with docked probe)
TÜV-CERTIFIED
TEST
E-MAIL: INTERNATIONAL@WOEHLER.DE INTERNET: WWW.WOHLER-INTERNATIONAL.COM
35
VISUAL INSPECTION
MEASURING INSTRUMENTS
LEAKAGE AND PRESSURE
SWEEP INSTRUMENTS
MEASURING INSTRUMENTS
IAQ/BUILDING
MEASURING INSTRUMENTS
FLUE GAS ANALYSIS