Installation Recommendations
Installation Recommendations
Mounting
The unit is designed to install into a standard 19" rack mounted at eye
level for best visual observation of the monitor screens.
Please refer to the system interconnect block diagram Figure 1–5 on
page 14 for clarification of the general signal paths into and out of the
AMP2A-10S unit.
Heat Dissipation
The ambient temperature inside the mounting enclosure should not
exceed 40° Celsius (104° Fahrenheit). Adjacent devices can be rack
mounted (or stacked) in proximity to the unit if the above temperature
is not exceeded. Allow a 1RU (1.75”/44.45mm) space above and below
the unit for air circulation.
Mechanical Bracing
Even though the unit is fairly heavy, the chassis is securely attached to
the front panel at eight points along its surface, not just at the four
corners of the chassis ears. This feature will reduce or eliminate rear
bracing requirements in many mobile/portable applications. The
weight of internal components is distributed fairly evenly around the
unit.
Note:
Be sure to set the level meter input level gain calibration and
VU/PPM display mode DIP switch (accessed through the
top cover) before installing the unit into an enclosed rack or
console.
Important:
To reduce noise, the monitor does not have any fans. As a result, the
heat generated by the power amplifiers, power supplies, and other
components is vented by slots in the side of the unit. Therefore, as a
safety precaution, we advise you to be sure to allow proper ventilation
on both sides of the unit.