User guide
© 2010 Wohler Technologies, Inc. All rights reserved.
13
AMP2A-10S User Guide
Technical Functional Diagram
2. Locate P2 on the 919030 bar graph driver PCB(s) you wish to
adjust. The P2 trim pot faces upward from the PCB edge. Of the
two trim pots visible (P1 and P2) it is the farthest from the front
panel as mounted to the chassis.
3. Connect an analog audio signal of an amplitude of approximately
1 kHz of the amplitude desired to give a “Peak” indication on the
bar graph (top segment) to the input of the bar graph you wish to
adjust.
4. Turning the P2 pot clockwise increases the displayed level
(sensitivity) of the associated bar graph meter. For example, to set
the Peak LED Segment level at +10.5 dBu (rather than the factory
default setting of +9.5 dBu), feed an analog audio signal of +10.5
dBu amplitude (as in Step 3) into the input on the rear panel, then
turn the P2 pot counter-clockwise as you visually monitor the
associated bar graph meter on the front panel until the desired
display setting (top segment) is achieved for the increased input
level. To peak the meters for a lower input level, you would turn
the pots clockwise to increase the displayed level for any
decreased input level.
Technical Functional Diagram
Figure 1–5 illustrates the overall functionality of the AMP2A-10S.