User guide

© 2010 Wohler Technologies, Inc. All rights reserved.
12
AMP2A-10S User Guide
Level Meter Bar Graph Fine Adjustment
Level Meter Bar Graph Fine
Adjustment
1. To remove the top cover, remove the top cover screws (2 along
upper front panel, 2 per each side, 3 along upper rear panel, and
1 center top). The 919030 PCBs (2 each) are vertically mounted to
the chassis bottom just behind the front panel-mounted LED bar
graph displays, one for each bar graph.
2. To adjust the pot locations and functions, locate P1 on the 919030
bar graph driver PCB(s) you wish to adjust. The P1 trim pot faces
upward from the PCB edge. Of the two trim pots visible (P1 and
P2) it is the closest to the front panel as mounted to the chassis.
3. Connect an analog audio signal of an amplitude of approximately
1 kHz of the amplitude desired to give a “0” indication on the bar
graph to the input of the bar graph you wish to adjust.
4. Turning the P1 pot clockwise increases the displayed level
(sensitivity) of the associated bar graph meter. For example, to set
the zero level at +7 dBu (rather than the factory default setting of
+4 dBu), adjust the level input gain calibration DIP switches for
gain closest to that desired. Feed an analog audio signal of +7 dBu
amplitude (as in Step 3) into the input on the rear panel, then turn
the pots counter-clockwise as you visually monitor the associated
bar graph meter on the front panel until the desired display setting
(“0”) is achieved for the increased input level. To zero the meters
for a lower input level, you would turn the pots clockwise to
increase the displayed level for any decreased input level.
Level Meter Bar Graph Peak LED
Segment Adjustment
1. Remove the top cover screws (2 along upper front panel, 2 per
each side, 3 along upper rear panel, and 1 center top). The 919030
PCBs (2 each) are vertically mounted to chassis bottom just behind
the front panel mounted LED bar graph displays; one for each bar
graph.