AMP2A-10S User Guide
Level Meter Settings and Specifications
Input Level Gain Calibration Settings
DIP switch sections 1 and 2 set the level meter Input Level Gain
Calibration, which determines the level of the input signal that will
result in a 0 reading on the meter bar graph. The factory setting is +4
dBu, but can be set for -6 dBu, 0 dBu, or +8 dBu by the user. See the
diagram below for settings.
Bar Graph Display Modes
DIP switch sections 3 and 4 determine how levels are displayed (PPM
or VU mode characteristics). The factory setting is VU. See the diagram
in Figure 1–4 below for settings.
Figure 1–4 DIP Switch Settings
Note:
Each bar graph segment will turn on at 0.5 dB before that
segment’s silk-screened scale indication.
Example: When the gain calibration is set for +4 dBu, the zero indication on the
level meter will light up at 3.5 dBu. Calibration is implemented in this
way to effect a rounding function for more accurate indication of signal
levels which occur between the thresholds of any two bar graph
segments.