User guide
821116: AMP2 -1 6 V S e r i e s U se r Guide
© 2 0 14 Wohler Te c h no l o g i e s, Inc. All rights re se r ved..
111
Chap ter 5 Menu List
Ha rdware Co nf igu ration Me nu
Figure 5–16 Hardware Configuration Menu
• Clock Source: Rotating this knob selects the input source for audio
clocking. You can use the
Ref
input on the rear panel to provide a
Genlock sync signal to which all sources are locked. To use this
connector, set this control to
Ref Genlocked
. If there is only one
input card and no
Ref
input, this is automatically set to that card. If
the currently-selected source is unlocked, the system will
automatically choose another locked source. When this happens,
the current source and the selected source fields will be different.
Clock problems are displayed in red on the
Main Screen
as shown
in Figure 5–17 below.
Figure 5–17 Genlock Lost Indicator on Main Screen
• Screen Saver: Rotate this knob to select the interval of time the
system will wait from the time the user last touched any of the front
panel controls, to the time that the system will dim the screens when
they are not being used.
Screen Saver
values can be
Off
(no
screen saver display) or from
5 Mins
to
24 Hrs
. Setting shorter
times will prolong the life of the front panel screens.
• Analog I/O Reference Level: Rotating this knob allows you to
select from any of the following eight analog I/O reference levels:
Hardware Configuration Menu
Save / ExitHelp Cancel
Unit
Info
Factory
Default
-20dBFS = +4 dBu
Analog I/O
Ref Level
Current: Internal Sync
Clock
Source
Selected Slot 4 (AES In) Pair 1
8 hours
Screen
Saver
Screen
Bright
Balance
Control
Menu Lock
SuperPair
Balance
Left Right
16 32
Im por ta nt :
You must set the
Clock Source
for each preset. This allows the
Clock
Source
to be quickly changed using a
Preset
hot key. All other
settings on this page affect all presets.
+0
Anlg
1
Dolby
5.1
0
-10 -10
0
D
o
D
o
A
E
A
E
A
n
A
n
GENLOCK LOST
Genlock Lost
Indicator