User guide
82 10 30: AMP x-S 8 S eries Use r Gu ide
© 2013 Wohl er Tec hn ologi e s , In c . Al l r ig h ts re se rved.
15
Ch ap te r 2 System Overview
Re a r P a ne l Co nn e cto r s
Figure 2–7 AES/PCM Input and Loop-Through
DB-25 Pin-Out
• 3G/HD/SD-SDI In (1 and 2, BNC-F): These inputs accept SDI video
signals for the 3G models.
Output Connectors
• Metered Analog (DB-25): This connector outputs the analog signal
that is displayed on the front panel level meters. The pin-out
information for this DB-25 is identical to that of the Analog Input
connector. See Figure 2–5 on page 14.
• 3G/HD/SD-SDI Re-Clocked Out (BNC): This connector outputs a
re-clocked copy of the SDI signal fed to the SDI input connector
selected for monitoring. When an SDI input is not selected for
monitoring in the unit, SDI In 2 will be reclocked and connected to
this output by default.
• AES Unbalanced Out from SDI (HD-15): This connector outputs
de-embedded audio. The last SDI input and group selection
Note:
The DA model does not feature SDI capability.
Note:
The Analog Output Preference (AOutputPref
AOutputPrefAOutputPref
AOutputPref) entry
within the Setup Menu determines how this connector
outputs the speaker assignment when a DM1, DM2, or
DM3 downmix selection is enabled. The default setting
is Downmix
DownmixDownmix
Downmix, which outputs the metered signal with
individual channel scaling (gain settings) intact as
determined by the selected downmix (DM1, DM2, or
DM3). If Discrete
Discrete Discrete
Discrete is selected, then all metered
channels are output from these connectors at unity gain.
See Analog Output Preference Mode on page 46 for
information on how to set this parameter.