User guide
82 10 30: AMP x-S 8 S eries Use r Gu ide
© 2013 Wohl er Tec hn ologi e s , In c . Al l r ig h ts re se rved.
11
Ch ap te r 2 System Overview
F ron t Pan e l C on tr ols
then they will display as short dashes. Each dash (-) indicates a
position for displaying the channel pairs available for monitoring
from left to right: 1/2, 3/4, 5/6 and 7/8. The unit updates the Input
Lock Status whenever it detects a signal change. See Figure 2–3
and below for an example.
Figure 2–3 Status Display Example: Standard Input
Source - HD-SDI Input 1
User Interface
Multi-Mode Color Codes
Most of the user interface buttons are multi-functional. They affect the
unit differently depending on whether they are used alone or in
combination with another button. The monitor’s front panels have
color-coded legends to help identify the different functions of each
button:
• White indicates normal operation.
MIX HD.SDI1 MIX
5 7
- - 6 8
GP3
GP4
Source Status
(HD-SDI Input 1)
Mix Status
(Custom)
Mix Status
(Custom)
Input Lock Status
(Channels 1 through 4 Not Locked;
Channels 5 through 8 Locked)
SDI Group
(Group # 4)
SDI Group
(Group # 3)
Table 2–1 White Control Functionality
Button Setup Mode Single-Channel Mode Pair Mode
Left Up
Selects the next option
for any given menu.
Attaches the left
speaker to the next
higher-numbered
channel.
Selects the next
higher-numbered
pair.
Left Down
Selects the previous
option for any given
menu.
Attaches the left
speaker to the next
lower-numbered
channel.
Selects the next lower-
numbered pair.