User guide

82 10 30: AMP x-S 8 S eries Use r Gu ide
© 2013 Wohl er Tec hn ologi e s , In c . Al l r ig h ts re se rved.
5
C hap te r 1 Installation
In st al lat ion R ec om m en da tio ns
Heat Dissipation
The ambient temperature inside the mounting enclosure should not
exceed 40° Celsius (104° Fahrenheit). Adjacent devices can be rack
mounted (or stacked) in proximity to the unit if this temperature is not
exceeded. Otherwise, allow a 1RU (1.75”/44.45mm) space above and
below the unit for air circulation.
Sympathetic Vibration
Sympathetic vibration from other equipment (cables, etc.,) in the rack
may be serious enough to interfere with the unit’s sound quality. The
use of thin card stock and/or felt or foam weather-stripping type
materials between adjacent vibrating surfaces, or tying up loose cables,
etc., may be required to stop vibrations external to the unit.
Mechanical Bracing
Even though the 2U models are fairly heavy, the chassis is securely
attached to the front panel. In addition, the chassis has mounting tabs
through which you attach it to the rack rail. This feature will reduce or
eliminate rear bracing requirements in many mobile/portable
applications. The weight of internal components is distributed fairly
evenly around the unit.
Connections and Cable Recommendations
We recommend that you limit the length of the cables that you use for
feeding HD-SDI signals sources to the HD-SDI inputs of the AMPx-E8
Series units and that you use a Belden 1694A cable (or equivalent).
Important:
To reduce noise, the monitor does not have any fans. As a result, the
heat generated by the class D power amplifiers, power supplies, and
other components is vented by slots in the side of the unit. Therefore,
as a safety precaution, you must allow proper ventilation on both sides
of the unit.
Note:
The connections of all DB-25 connectors are compatible with
Tascam DB-25 to XLR cable assemblies. Consult the factory
for availability. All rear panel connectors are female except
for the XLR connectors.