Copying a Configuration File from the AMP1-16-M
1. To copy a configuration file from the AMP1-16-M to the flash drive, press
Save from the Flash Drive Options screen. The Save to Flash Drive screen
will display as shown in
Figure 2–7. The lighter color buttons indicate file
numbers that already contain configuration data.
Figure 2–7: Save to Flash Drive Screen
2. Press the file number (
File 1 through File 7) of the file you want to copy
from your flash drive. When the copy process completes, the
Flash Drive
Options
screen re-displays.
3. Remove the flash drive from the USB port.
Update Menu
This button only appears if the inserted flash drive contains a software update files.
Press this button to proceed to the software updating menu. Appendix D describes
in detail the procedure to update the AMP1-16-M software from a flash drive.
You can copy the software update files to a flash drive using the Wohler AMP1-16-M
Manager program in your PC. Refer to The USB Tab in Chapter 3 for adding a
software update to a flash drive.
If you prefer to update the AMP1-16-M software using a direct Ethernet connection
to a PC, refer to Appendix B for step by step instructions.
To update the AMP1-16-M software remotely using an Ethernet connection from a
network, refer to Appendix C for step by step instructions.