AMP1-VS and AMP1-VSA User Manual P/N 821613, Rev-B Section 2: Operation
(Continued)
G
E
D
A
B
C
F
Please refer to Figure-2b on the facing page to familiarize yourself with the rear panel features of the AMP1-VS and AMP1-VSA
unit. The following sections describe these features and are referenced, by letter, to Figure-2b.
Rear Panel Features
Power Connector
Attach a standard IEC-320 power cord between this connector and mains power (100 - 250VAC, 50/60 Hz). The front panel
Power LED (Item 7, page 8) will glow GREEN to indicate operating voltages are present.
Analog Output (From SDI IN) Connectors (1-4)
These four 3-pin male Phoenix connectors output analog signals de-embedded from the SDI IN input connector (Item D) and are
configured for balanced low impedance connections. These connectors continuously output an analog signal converted from the
SDI inputs and are not affected by any selection settings. Connector pin-out information is silk-screened on the rear panel.
Digital Input Level Gain Calibration DIP Switch
Input Level Gain Calibration, the analog level which corresponds to a given digital input value, is settable via this DIP
switch. The factory setting is +4 dB (analog) = -20 dBFS (digital). See the silk-screened chart on the rear panel or the
diagram below for settings.
SDI Input and Output Connectors
The female BNC SDI IN connector receives industry standard SDI formatted signals and is configured for an unbalanced,
75 connection. The unit de-embeds and monitors sub-group 1 (channels 1/2) and sub-group 2 (channels 3/4) of SDI
Group ID #1 (see page 17 for more information). Note that in the AMP1-VSA model, the SDI input is monitored only
when the Analog/Digital Source Select Switch (Item 5, page 8) is set to DIGITAL.
The female BNC SDI OUT loop-through connector outputs a reclocked (regenerated) copy of the signal entering the SDI
IN input connector and is configured for an unbalanced, 75 connection.
Level Meter DIP Switch
This DIP switch sets the Line Level Calibration, Reference Level, and PPM/VU Display Mode for the level meter LED
bargraph displays on the front panel. See page 19 for for setting information.
Selected Analog Output Connectors (Right [A] and Left [B])
These two 3-pin male XLR connectors are analog outputs of the selected source(s) as assigned to the left and right
speakers. The left connector outputs the left channel (Channel A) and the right outputs the right channel (Channel B).
Both connectors are configured for low impedance connections and the output signals are not affected by the volume/
balance controls or headphone mute. For XLR pinout information see the diagram below.
Analog Input Connectors (CH. 1 - CH. 4)
These four 3-pin male Phoenix connectors, featured only on the AMP1-VSA model, accept standard analog audio signals
and are configured for balanced 200K connections. Note that in the AMP1-VSA model, the Analog inputs are monitored
only when the Analog/Digital Source Select Switch (Item 5, page 8) is set to ANALOG.
High (+)
Low (-)
Gnd
(Shield)
Pin-1 Pin-2
Pin-3