General Purpose Inputs and Outputs (GPI/Os)
2. Follow the instructions in Appendix B on page 89 to establish
connectivity to the AMP1-16 Series monitor.
3. Follow the instructions in Appendix C on page 97 to set up the
AMP1-16 Series monitor for an FTP file transfer.
4. Drag and drop the Presets.S19 file (or the file you renamed in
Step 6 at the top of this page) from your
Presets folder to the
AMP1-16 Series monitor.
5. Press the Help (left) navigation button on the AMP1-16 Series
monitor to restart it and load the new presets into memory.
General Purpose Inputs and Outputs
(GPI/Os)
The AMP1-16-3G contains eight General Purpose Inputs (GPIs) and
two General Purpose Outputs (GPOs). The inputs (GPIs) are detected
as DC voltages between 12 and 24 VDC. Their action replicates the
action of the hot keys on the front panel. Since you can assign the action
of the hot keys to a variety of functions using the
Main Screen Hot
Key Button Configuration Menu
, the GPIs can therefore change
presets, mute sets of channels, or solo sets of channels.
The first General Purpose Output (GPO) is activated when the loudness
is equal to or greater than a level set using the GPO activate function in
the
Loudness Configuration Menu. The second GPO is not used,
Note:
Transferring the preset file to the AMP1-16 Series
monitor will reset it and then it will return to the ftp-
enabled state.
Important:
This concludes the entire preset copying procedure.