User guide
821697: AMP1-16 Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
14
Chapter 2 Audio and Metering
Configuring the Audio Outputs
4. Next, press the AES Channel Pair button and then rotate the
Balance knob to select the AES pair that will receive the Monitor
Downmix
. In our example in Figure 2–4 below, we selected
Channel Pair 1/2.
Figure 2–4 Select Outputs
5. When the outputs you want are highlighted, press the AES
Output = Source Select
button again and then rotate the
Balance knob to select Monitor Downmix source. See Figure 2–
5 on page 14 for the display.
Figure 2–5 Select Monitor Mix for the Input
6. You can repeat this procedure on other AES or analog outputs if
you need additional duplicate monitor mix outputs. Press the
button twice to return to the Main Screen.
AES Output Configuration Menu
AES Output Channels 1/2 AES Output Channels 3/4
+0 +0 +0 +0
Level Trim
21 21 43 43
Affected by
Volume Control
Affected by
Solos & Mutes
Output Mute
With Headphone
AES Output =
Selected Sources
No
No
No
No
Yes
SDI In Channels 7/8SDI In Channels 5/6
Channel Output
AES Channel Pair
AES Output Configuration Menu
AES Output Channels 1/2 AES Output Channels 3/4
+0 +0 +0 +0
Level Trim
21 21 43 43
Affected by
Volume Control
Affected by
Solos & Mutes
Output Mute
With Headphone
AES Output =
Selected Sources
No
No
No
No
Yes
SDI In Channels 3/4Monitor Downmix Pair
Channel Output
AES Channel Pair