User guide

821697: AMP1-16 Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
12
Chapter 2 Audio and Metering
Configuring the Audio Outputs
1. From the Main Screen, press either the button or the
button to display the
Configuration Menu.
2. From the
Configuration Menu, select either the AES Output
Configuration Menu
or the Analog Output Configuration
Menu
depending on the output type you want to use. In our
example, we’re using the
AES Output Configuration Menu.
3. If needed, press the
AES Output = Selected Sources button
and then press the
Balance knob to display AES Output =
Monitor Channels
. This will set the outputs so that they match
those viewed on the meters in the Main Screen.
Figure 2–2 AES Output = Monitor Channels
4. You can also specify whether the outputs should be affected by:
A. The Solo and Mute hot keys (available per channel pair), by
pressing the
Affected by Solos and Mutes button.
B. The front panel
Volume control (available per channel pair),
by pressing the Affected by Volume Control button.
C. Inserting a pair of headphones to mute the output audio
channels (available system-wide), by pressing the Output
Mute with Headphone
button.
Stereo Downmix
If a studio or other monitoring environment contains a stereo sound
system, it may be advantageous to connect the monitored sound from
the AMP1-16 Series monitor to this system. One or more of the AES or
AES Output Configuration Menu
AES Output Channels 5/6 AES Output Channels 7/8
+0 +0 +0 +0
Level Trim
Affected by
Volume Control
Affected by
Solos & Mutes
Output Mute
With Headphone
Channel Output
No
Yes
Yes
Yes
Yes
AES Output =
Monitor Channels
65 65 87 87
SDI In Channels 7/8SDI In Channels 3/4
AES Channel Pair