Chapter 1 Quick Start
Installation Recommendations
Installation Recommendations
Mounting
The unit is designed to install into a standard 19" rack, mounted at eye
level for best visual observation of the monitor screens. After installing
the AMP1-16-3G, remove the clear, plastic protective covers from each
screen using the tabs provided.
Heat Dissipation
The ambient temperature inside the mounting enclosure should not
exceed 40° Celsius (104° Fahrenheit). Adjacent devices can be rack
mounted (or stacked) in proximity to the unit if the above temperature
is not exceeded. If the product must be operated in an environment
with an elevated temperature, allow a 1RU (1.75”/44.45mm) space
above and below the unit for air circulation.
Power
The AMP1-16-3G has a standard IEC connector on the rear panel from
which it can connect to AC mains power (100 to 240 VAC ± 10%, 50/60
Hz, 65W). You may use the power cord provided, or another approved
cord, to adapt the unit to the proper country-specific power connection.
FCC Compliance
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
Important:
To reduce noise, neither the AMP1-16-3G nor the AMP1-E16-3G have
any fans. As a result, the heat generated by the class D power
amplifiers, power supplies, and other components is vented by slots in
the sides of the unit. Therefore, as a safety precaution, we advise you to
be sure to allow proper ventilation on both sides of the unit.