Rear Panel 10-Position DIP Settings for the Level Meters
PPM Characteristics (Ballistics)
The PPM characteristics determine the Integration Time (rise time) and
Return Time (fall time) of the level meter. The Integration Time is the
time it takes for the lighted segments of the level meter, after
application of a 5 Khz tone at a certain reference level, to rise within a
specified number of dB of that level. Return Time is the time it takes for
the lighted segments of the level meter to fall a certain number of dB
after removal of a 5 Khz tone of a certain reference level. The PPM
characteristics available for selection using DIP switch sections 7 and 8
of the 10-position Internal DIP Switch are shown in Table 1–2 below.
Phase Correlation
Since it is sometimes helpful to observe phase relationships between
two signals being monitored, you can enable a Phase Correlation
feature within the lower section of the existing bar graph pair in the
AMP1-DA/106 units. Set the internal 10-position DIP switch located on
the PCB. The labels for this feature (Figure 1–11 on page 18) can be
specified at the time of order or requested from Wohler for application
to existing units.
Table 1–2 PMP Characteristics
Type Rise and Fall Times
IEC268-10, Type 1
Integration (Rise) Time is 5 ms (-2 dB).
Return (Fall) Time is 1.7 seconds (20 dB).
IEC268-10, Type 2
Integration (Rise) Time is 10 ms (-2 dB).
Return (Fall) Time is 2.8 seconds (24 dB).
DIN 4506
Integration (Rise) Time is 5 ms (-2 dB).
Return (Fall) Time is 1.5 seconds (20 dB).
Single Sample
Integration (Rise) Time is a single sample.
Return (Fall) Time is 1.5 seconds (20 dB).