AMP1-DA/106 User Guide
Rear Panel Connectors
AES/EBU In (In 1 and In 2): These two female BNC input connectors
(In 1 and In 2) accept standard AES/EBU signals. These connectors are
configured for unbalanced, 75 connections. Only one of the two AES/
EBU inputs may be monitored at a time. Use the Digital Source
Select Switch
on the front panel to select between AES/EBU inputs In
1
and In 2. Note that the unit will monitor the selected AES/EBU channel
only when the
Analog/Digital Source Select switch on the front
panel is set to Digital.
AES/EBU Input Level Gain Calibration DIP Switch: Set the
Input Level Gain Calibration, the analog level that corresponds to a
given digital input value with this DIP switch. The factory setting is +4
dB (analog) = -20 dBFS (digital). See the silk-screened chart on the
rear panel or Figure 1–6 on page 13 for settings.
Figure 1–6 AES D/A Conversion Gain Calibration
Settings
Selected Analog Out (Left and Right): These two 3-pin male XLR
connectors (
CH.A(L) and CH.B(R)) are analog outputs of the
selected digital source as selected for the left and right speakers and
level meters. Both connectors are low impedance. The output is not
affected by the volume/balance controls or headphone mute. See
Figure 1–7 below for pin-out information.