User guide
821024: AMP1-DA/106 User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
11
AMP1-DA/106 User Guide
Rear Panel Connectors
• Analog/Digital Source Select Switch: When this toggle switch is
set to analog, the unit will monitor the analog input signals from the
Analog In XLR connectors on the rear panel. When this toggle
switch is set to Digital, the unit will monitor the selected AES/EBU
In
input (In 1 or In 2) on the rear panel.
• Volume Control: This controls the loudness of the audio
reproduced by the internal speakers or connected headphone.
Clock-wise rotation of this control increases the loudness of the
monitored audio.
• Power LED: This LED glows green to indicate the unit is connected
to operational mains power.
• AES/EBU Signal Status Indication LED: This LED indicates the
status of the currently selected AES digital signal (AES 1 or AES 2)
regardless of any other monitor selection settings. This LED glows
green as long as a valid AES digital datastream is being received. It
will glow red to indicate errors in the reception of the AES signal.
There are two DIP switch selectable modes of fault detection that
will create a red LED error indication.
• Balance Control: This adjusts the volume balance between the left
and right speakers.
Rear Panel Connectors
Figure 1–3 AMP1-DA/106 Rear Panel
• Power: Attach a standard IEC-320 power cord between this connector
and mains power (100 - 250VAC, 50/60 Hz). The front panel Power LED
will glow green to indicate operating voltages are present.
Power AES Termination
AES In 1 and 2
Gain
Selected Analog (Out from AES)
Left and Right
Calibration
Analog In Left and Right