User guide

© 2010 Wohler Technologies, Inc. All rights reserved.
15
AMP V Series User Guide
Rear Panel Connectors
AES Termination (Four-Position DIP Switch): This DIP switch sets
the termination for the AES inputs. If an AES input channel is fed to
downstream equipment, the associated DIP switch must be in the
up position (unterminated). If no downstream equipment is
connected, the switch must be in the down position (terminated).
See Figure 1–8 for details.
Figure 1–8 AES Termination DIP Switch Settings
Analog Input (3-Pin Phoenix Male, Channels 1 through 4): These
connectors accept standard analog audio signals and are configured
for balanced 90K Ω connections. The banks (groups) of input
connectors are interleaved and either group of four inputs (Group 1
or Group 2) may be selected for monitoring using the two-position
Group select switch on the front panel. Channel input numbers are
silk-screened above the connectors (Channel 1, 2, 3, 4) and
correspond to the numbers available for selection by the left and
right Speaker Assign channel buttons on the front panel.
Connector pinout information is silk-screened just above each
connector.
AES Gain Calibration (Two-Position DIP Switch): This DIP switch
calibrates the AES analog level that corresponds to a given digital
input value. The factory setting is +4 dB (analog) = -20 dBFS
(digital).
Figure 1–9 AES Gain Calibration DIP Switch
Settings