User guide
821027: AMPx-SDA User Guide
© 2012 Wohler Technologies, Inc. All rights reserved.
12
AMPx-SDA User Guide
Rear Panel Connectors
• AES Error Indication Type: There are two DIP switch
selectable modes of AES error detection that will create a RED
error indication in the AES Signal Error Indication LED on the
front panel;
1) Reception errors: errors in reception of data or no data
stream at all (S1=Down), or
2) Reception and data errors: errors in reception and data
errors identified by the sending device (possibly invalid)
(S1= Up). See Figure 1–4 for AES error DIP switch
settings.
Figure 1–4 AES Error Indication Settings
• AES Input Connector: The AES/EBU IN input connector is meant to
receive standard AES/EBU signals. This female BNC connector is
configured for an unbalanced, 75 connection. Note that the unit will
monitor the
AES/EBU In input only when the Analog/Digital
Source Select
switch is set to Digital and the Digital Source
Select
switch is set to AES.
• AES Input Level Gain Calibration DIP Switch: Input Level Gain
Calibration, the analog level which corresponds to a given digital
input value, is settable via this DIP switch. The factory setting is +4
dB (analog) = -20 dBFS (digital). See the silk-screened chart on the
rear panel or the diagram below for gain calibration settings.
Note
Position 3 is not used.