AMP1-MADIe 1RU, 8 of 64 Channel, MADI Audio Monitor User Guide (Software Release: V1.
© 2012 Wohler Technologies, Inc. All rights reserved. This publication is protected by federal copyright law. No part of this publication may be copied or distributed, stored in a retrieval system, or translated into any human or computer language in any form or by any means electronic, mechanical, manual, magnetic, or otherwise, or disclosed to third parties without the express written permission of Wohler Technologies. Reproduction Licensed users and authorized distributors of Wohler Technologies, Inc.
Table of Contents Chapter 1. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Introduction ...................................................................1 Overview..................................................................1 Topics ......................................................................1 Safety ...........................................................................2 Instructions ..............................................................
Default Presets ........................................................13 Selecting Any Eight Channels ....................................14 Adjusting the Volume of Each Channel..............................15 Adjusting the Speaker Audio Tone Controls .......................15 Selecting the Multimode Optical Input ..............................16 Using the Balanced Analog Outputs..................................17 Pre Fade or Post Fade Metering........................................
Analog Output......................................................... 31 Audio Delay ............................................................ 32 Functions Enabled ................................................... 32 Tone Controls.......................................................... 32 Channel Knob Acceleration........................................ 32 Menu Lockout Override .................................................. 33 The Ethernet Tab.....................................................
Appendix A. Connecting the AMP1-MADIe to a LAN. . . . . 53 Introduction..................................................................53 Overview ................................................................53 Topics ....................................................................53 Requirements ...............................................................54 Downloading the Installation File .....................................54 Installing the AMP1-MADIe Manager ...............................
CHAPTER 1 Installation Introduction Overview The AMP1-MADIe is a 1RU, eight of 64 channel MADI audio monitor. This unit comes with two 2.4” graphics screens that display eight channels of audio level metering. Any eight channels in the MADI stream may be audibly and visually monitored. The AMP1-MADIe is small, low-cost, and simple to operate. Its setup configuration can easily be copied to other AMP1-MADIe units. Note that very little configuration should be necessary.
C h a p t e r 1 I n st a l la t i o n Safety Safety Instructions IMPORTANT: 1. Read, keep, and follow all of these instructions; heed all warnings. 2. Do not use this equipment near water. 3. Use only a dry cloth to clean the equipment. 4. Do not block any ventilation openings. 5. Do not install near any heat source such as a radiator, heat register, amplifier, or stove. 6. Do not attempt to plug the unit into a two-blade outlet (with only two prongs of equal width).
C h a p t e r 1 Installation Safety Safety Symbols WARNING: The symbol to the left warns of electric shock hazard inside the unit. Disconnect the power cord before removing access panels when installing upgrades. Only qualified service personnel are to operate the equipment with covers removed, and are to exercise caution to avoid personal injury. Mounting The unit is designed for a standard 19" rack.
C h a p t e r 1 I n st a l la t i o n Compliance weather-stripping between the vibrating surfaces. Tie loose cables securely with cable ties. Mechanical Bracing The 1RU chassis is securely attached to the front panel. In addition, the chassis has mounting tabs through which you attach it to the rack rail. This feature will reduce or eliminate rear bracing requirements in many mobile/portable applications. The weight of internal components is distributed fairly evenly around the unit.
C h a p t e r 1 Installation Front Panel frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. ICES-003 This Class A digital apparatus complies with Canadian ICES-003.
C h a p t e r 1 I n st a l la t i o n Front Panel • Power Indicator: This tri-color LED indicates power and basic status information. See Table 1–1 below. Table 1–1 Power Color/Indication Descriptions LED Color Green Red Yellow Off Description The AMP1-MADIe is functioning normally. When the LED flashes green or yellow followed by a series of red flashes, each flash sequence indicates an error code. Try restarting the unit, and if the problem persists, contact Wohler Technical Support.
C h a p t e r 1 Installation R e ar P a n e l Rear Panel Figure 1–2 Rear Panel Layout Analog Audio Outputs (Left, Mono Mix, & Right) BALANCED ANALOG OUT MADI IN OUT LEFT MONO MIX RIGHT MADI OUT IN ETHERNET 100-240 VAC 50/60 Hz Power MADI I/O 1 and 2 (Inputs and Outputs) Ethernet • Power: The AMP1-MADIe uses a standard IEC power cord for the 100 to 240 VAC ±10%, 50/60 Hz power connection. • MADI Inputs: (1 Coax, 1 Optical) These two connectors accept either 56- or 64-channel MADI input signals.
C h a p t e r 1 I n st a l la t i o n M a i n S cr e e n Main Screen After powering up the AMP1-MADIe and connecting a MADI signal to one of the inputs, you will see the Main Screen, similar to the one shown in Figure 1–3 below.
C h a p t e r 1 Installation M a in Sc re en blue channel icons. Rotate the Channel Volume knob to adjust the level of the highlighted channel(s). The narrow bar under each level meter shows the position of the Channel Volume knob for each channel. The yellow Channel Volume knob always works for only the yellow highlighted channels. Adjust the Master Volume and Balance controls as necessary. You can also give the channels unique names.
CHAPTER 2 Operation Introduction Overview This chapter describes how to operate the AMP1-MADIe’s Main Screen and how to transfer configuration files to/from a flash drive.
C h a p t e r 2 O p e ra t i o n In it i a l Oper a ti o n Initial Operation When you first power your AMP1-MADIe, it will be ready to monitor the first eight MADI channels from the BNC input. Turning up the Master Volume will let you hear all eight channels at once. By default, the odd-numbered channels will sound in the left speaker, and the even-numbered channels will sound in the right speaker, but you can easily change this any way you like.
C h a p t e r 2 Operation Selecting Different Channels for Monitoring Selecting Different Channels for Monitoring Default Presets By default, the eight presets in the AMP1-MADIe are set up to monitor the 64 MADI channels as shown in Table 2–1 below.
C h a p t e r 2 O p e ra t i o n S e l e c ti n g D if f e r e n t C h a n n e l s f o r M o n i to r in g Figure 2–3 Preset Action Menu Preset Action Current Config: Default 1 Selected Preset: Default 8 (Preset 8) Recall Recall this Preset Save Save the current config to this Preset Exit with no changes at all Exit Press the Recall button. Now the second eight channels, 9 through 16 will be monitored. Press the Exit button to return to the Main Screen.
C h a p t e r 2 Operation A d j u s t i n g t h e V o lu m e o f E a c h C h a n n e l • Press the Channel Volume knob to select where you want to monitor this channel: the Left, Right, or Center (both channels). • Rotate the Channel Volume knob to select a MADI channel. Note: The channel names shown cannot be changed from this menu. They can be changed from the Manager software. Refer to Chapter 3. Repeat this with other channels as needed.
C h a p t e r 2 O p e ra t i o n S e l e c ti n g th e M u l t im o d e O p ti c a l I n p u t Figure 2–5 Audio Menu 2 Audio Menu 2 Flat Tone Controls Flat response, tone controls set to 0 dB Bass 0 dB Treble 0 dB 4 ms Audio Delay The Tone Controls affect the speaker sound only. Back Next To quickly exit Menus, press Channel Volume for 3 seconds Pressing the Flat button brightens the Flat setting and darkens the Bass and Treble settings to brown, and produces a flat response.
C h a p t e r 2 Operation Using the Balanced Analog Outputs Figure 2–6 Options Menu Screen Bright Screen Saver Options Menu Left Right 22 22 Press to select, then turn the Trim control to adjust . 8 hrs MADI Input Coax Copper Input BNC Multimode Fiber Input Fiber ON Chan Volume Acceleration Back Next To quickly exit Menus, press Channel Volume for 3 seconds In this menu, press either BNC or Fiber. Press the Channel Volume knob for at least three seconds.
C h a p t e r 2 O p e ra t i o n Pre Fade or Post Fade Metering Figure 2–7 Audio Menu 1 Audio Menu 1 Never Mute Mute with Headphone Speaker Mute Analog Outputs Not even when headphones are plugged in Fixed Level, Mute Controlled Whenever headphones are plugged in Master Volume/Balance Controlled Always Mute Audio may only be monitored from analog outputs or headphones Channel Volume Controlled Back Fixed Master Volume Channel Volume Next To quickly exit Menus, press Channel Volume for 3 seco
C h a p t e r 2 Operation S a v in g Y o u r S e t t in g s Press the Metering Mode button to change between Post Fade and Pre Fade. Then press the Back or Next buttons several times to exit to the Main Screen. Saving Your Settings Once you have set up your AMP1-MADIe exactly the way you want it, you will probably want to save the settings for a quick recall, just in case someone else accidentally disturbs them. To do this, simply press the Select Preset button.
C h a p t e r 2 O p e ra t i o n USB Port Functionality Press Save and your settings will be instantly saved. USB Port Functionality You can copy configuration files to and from your unit by a flash drive connected to the USB port. Immediately after connecting the flash drive to your AMP1-MADIe, the Flash Drive Connected screen displays (interrupting any current functions except an Ethernet connection) as shown in Figure 2–11 below.
C h a p t e r 2 Operation USB Port Functionality Figure 2–12 Get a Setup From the Flash Drive Screen Get a setup from the Flash Drive File 1 File 5 Select the Flash Drive file number 1 to 7 from which to get a new AMP1-MADIe configuration File 2 File 3 Cancel/Quit From the bright green choices, select the configuration file you want to copy from the flash drive to the AMP1-MADIe. If you change your mind and no longer want to get a file, press the Cancel/Quit button.
C h a p t e r 2 O p e ra t i o n USB Port Functionality 22 821091: 2. The bright blue choices indicate files that already exist. Press the file number that you want to copy the AMP1-MADIe configuration to (including all eight presets plus the current configuration). If you change your mind and no longer want to save a file, press the Cancel/Quit button. Once the copy process completes, the Flash Drive Connected screen re-displays. 3. Remove the flash drive from the USB port.
CHAPTER 3 AMP1-MADIe Graphical User Interface (GUI) Manager Introduction Overview This chapter describes how to use the AMP1-MADIe Manager to the configure the AMP1-MADIe. I m p o rt a n t : If you have not yet installed the AMP1-MADIe Manager setup software on your PC and connected it to the AMP1-MADIe, you must complete all the steps in Appendix A on page 53 before continuing.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r R u n n in g t h e A M P 1 - M A DI e M a n a g e r Running the AMP1-MADIe Manager The AMP1-MADIe Manager allows you to customize the monitor’s configuration to perfectly suit your needs.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager The Channels Tab • Open from PC: Clicking this button displays the Windows Open dialog so you can open a configuration file on your PC. • Send to Unit: Clicking this button sends a setup overwriting AMP1-MADIe’s current configuration (including options and presets). This AMP1-MADIe will then automatically be set to the configuration saved in Preset 1.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r T h e P re se t T a b s The Preset Tabs Since all the Preset tabs are identical we will only show the first one to explain the settings it provides for each preset. Figure 3–3 Preset 1 Tab Wohler AMP1-MADIe Manager v01.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager The Current Tab • Speaker Assignment: Click the drop-down menu to select the speaker(s) you want to hear this channel in: Left, Center (both), or Right. The Channel Assignment icon will change accordingly. Channel Volume dB Channel Volume: Select the volume for this channel from -61 dB to 0 dB. • Setting a volume to -61 dB displays Mute in the selection field. • Setting a volume to 0 dB displays Max in the selection field.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r The Facility Tab Note: The name of the Current Preset cannot be changed: it is always called the Current preset. You can, however, use this screen to perform all of the following: 1. Copy the settings from another preset into this one using the Copy Settings from Preset button. Enter the preset number and then click the button. 2. Select any MADI channel to any monitoring position.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e O p t io n s T a b When you start the AMP1-MADIe Manager, it automatically recalls the Facility configuration file. The settings in the Facility configuration file copy over the settings in the Channels tab, the Preset tabs, and the Options tab. You can send this configuration to the selected AMP1-MADIe without changes, or you can modify it and then send it to the selected unit. The controls on the Facility tab are listed below.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r The Options Tab Level Meters • Click the drop downs to select the Scale, and then the Float, and Bar for your level meter display. Alternatively, you can click the Meter Scale Default button to return to the defaults for the chosen meter scale.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e O p t io n s T a b Input Selection The AMP1-MADIe comes with two inputs, BNC and optical. Click the input you wish to use. Screen Brightness Select the screen brightness for each screen and the duration for the screen saver. • Left/Right: Either click the down arrow to increase or decrease the screen brightness value, or click the field and type in a value.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r The Options Tab • Master Volume Controlled: The volume of the outputs is controlled by the Volume and Balance knobs on the front panel. Note: The Analog Output can be both Channel Volume Controlled and Master Volume Controlled. Audio Delay Click either No Delay, or click the up or down arrows to either increase or decrease the amount of audio delay time from 0 (default) to 170 ms in 1 ms increments.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager M e n u L o c k o u t O v e r ri d e • Off: Turns the Channel Knob Acceleration off. When Channel Knob Acceleration is turned off, the action is always one step per click, regardless of how fast you rotate the knob. Menu Lockout Override Even though you may have disabled the menu access in the The Options Tab on page 29, you can override this lockout to gain access to the menu system.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r The Ethernet Tab The Ethernet Tab Figure 3–8 Ethernet Tab Wohler AMP1-MADIe Manager v01.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e Et h e rn e t T a b Units Responding The large window in the Units Responding area displays all the AMP-MADIes that the application found on the network. • Refresh: Clicking this button causes the system to poll the network to find all the AMP1-MADIes on the network. • Locate IP: Clicking this button displays the Enter AMP1-MADIe IP Address dialog.
C h a p t e r 3 A M P 1 - M A D I e G ra p h ic a l U s e r I n t e r f a c e ( G U I ) M a n ag e r The USB Tab • Manual: Clicking this button allows you to read this document in .pdf format. The USB Tab Using a Flash Drive You can use a USB flash drive to transfer settings from one AMP1-MADIe to another, and to or from any Windows computer. This tab allows you to save or retrieve files from a USB flash drive attached to the host computer.
C h a p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager The USB Tab connected. Clicking on any one of the files (or the empty file positions) selects it for other operations. • Read from Flash: Clicking on the Read from Flash button loads the selected file into the program. This button is disabled if a valid flash drive file is not selected. The system will only read the files from the \Wohler folder on the flash drive.
CHAPTER 4 Internal Menu System Introduction Overview This chapter provides an in-depth description of all the features, specifications, and menus and all their respective options and functions. I m p o rt a n t : The AMP1-MADIe local menus cannot be used at the same time that the PC setup software is connected. If this happens, the PC setup software will take precedence and display the words Remote Access notifying you about the PC connection.
C h a p t e r 4 I n t e rn a l M e n u S y st e m M e n u N a v i g a t i o n O v e rv i e w Menu Navigation Overview You can launch the menu system by pressing and holding the Channel Volume knob for three seconds. Navigate the menu tree with the Back and Next buttons at the bottom of each screen.
C h a p t e r 4 Internal Menu System A u d io M e n u 1 • Back: Pressing this button closes this menu and opens the previous menu, one step up the menu tree. • Next: Pressing this button closes this menu and opens the next menu, one step down the menu tree. • Pressing a menu setting button will light the button name in yellow if it requires the use of the yellow Channel Volume control for its adjustment. Audio Menu 1 This menu allows adjustment of various audio related settings.
C h a p t e r 4 I n t e rn a l M e n u S y st e m Audio Menu 2 • Fixed: Pressing this button prevents the Master Volume and Channel Volume controls from affecting the analog outputs. They will output all unmuted channels at a fixed line level. • Master Volume: Pressing this button enables the Master Volume and Balance controls to affect the analog outputs. This setting can be convenient to use when monitoring is always done through the analog outputs with external amplifiers and speakers.
C h a p t e r 4 Internal Menu System Options Menu • Bass: Pressing this button and then turning the Channel Volume knob adjusts the bass response up or down in 2 dB steps to as low as -12 dB or as high as +12 dB. • Treble: Pressing this button and then turning the Channel Volume knob adjusts the treble response up or down in 2 dB steps to as low as -12 dB or as high as +12 dB. • Audio Delay: You can add up to 170 ms of delay to the speaker and analog outputs in one ms increments.
C h a p t e r 4 I n t e rn a l M e n u S y st e m Meter Type and Reference Menu minutes to 119 minutes (in 1-minute increments) and from 2 hours to 24 hours (in 1-hour increments). The default setting is 8 hours. If the AMP1-MADIe is in operation for the screen saver time out period and no front panel controls have been turned or pressed, the screens will dim by a certain amount. If double the screen saver time out period elapses without any front panel control activity, the screens will dim further.
C h a p t e r 4 Internal Menu System Meter Type and Reference Menu • Scale: Pressing this button and then rotating the Channel Volume knob steps through the scales for the level meters. Six selections are available as shown in Table 4–1 below. Table 4–1 Meter Limits and References Default Reference Default Color Bounds Lower Upper Bottom Limit Top Limit AES -72 dBFS 0.0 dBFS 0 dBFS = 0 dBFS -30 dBFS -20 dBFS VU Extd VU BBC (EBU) Nordic DIN -45 dBr -56 dBr +3.5 dBr +16.
C h a p t e r 4 I n t e rn a l M e n u S y st e m Meter Segment Menu Meter Segment Menu On the Meter Segment Menu, you can customize the look of your meters. Figure 4–6 Meter Segment Menu Meter Segment Menu Upper Segment -20 dBFS Middle Segment -30 dBFS 0 -10 23 Upper Color 19 Middle Color 13 Lower Color -20 Set Default -30 Press a Segment or Color button and then turn the Trim control to adjust.
C h a p t e r 4 Internal Menu System Version and Ethernet Menu Version and Ethernet Menu This menu displays software and hardware versions, as well as Ethernet settings. By default, the DHCP setting is enabled and the IP Address and IP Mask settings are shown as 0.0.0.0. This means it will automatically attempt to get the needed IP Address and IP Mask settings from the network.
C h a p t e r 4 I n t e rn a l M e n u S y st e m Version and Ethernet Menu I m p o rt a n t : If the IP information has been changed, the unit will have to restart. A warning diamond will display, and you will need to confirm or cancel before proceeding. If the information in the IP fields is not correct, the changes made in the IP fields will be ignored. The IP address is valid if the screen reads “DHCP Mode Enabled” or “Static IP Mode Enabled.
CHAPTER 5 Features and Specifications Introduction Overview This chapter lists the features and specifications. Topics Topics Introduction Page 47 Features 48 Specifications 49 Technical Functional Overview 50 8 2 1 0 9 1 : A M P 1 - M A D I e Us e r G u i de © 2 0 1 2 Wo h l e r Tec h n o l o g i e s, I n c. A l l r i g h t s r e s er ved .
C h a p t e r 5 F e a t u r e s a n d S p e c i fi c a ti o n s Features Features • Totally digital system architecture with high fidelity Class D amplifiers • Coax MADI input and output with passive power fail bypass • Optical MADI I/O • Reclocked BNC coax and Optical MADI outputs. • Automatic format conversion from coax to optical or optical to coax.
C h a p t e r 5 Features and Specifications S p e c if i ca t i o n s Specifications Table 5–1 Specifications Specification Power requirements Power consumption Dimensions (H x W x D) Weight Space Required Supplied Accessories Display Type Number of Displays Screen Size Screen Resolution Sample Rate De-Multiplexing Inputs Values/Domains 100 V to 240 V AC ± 10%, 50/60Hz 60 Watts 1.75” x 19” x 4.25” (44mm x 483mm x 107mm) 5 lbs. (2.
C h a p t e r 5 F e a t u r e s a n d S p e c i fi c a ti o n s Technical Functional Overview Table 5–1 Specifications (Continued) Specification MADI to Analog Output Delay MADI Input to MADI Output Latency Values/Domains 1 ms to 170 ms adjustable 10ns Selectable: • AES, • DIN, Level Meter Scales • BBC, • EBU, • Std VU, • Ext VU, • Nordic Selectable: • Meter thresholds, Level Meter Characteristics • Reference, • Segment Colors, and Peak Acoustic Output Power Output RMS Acoustic Frequency Response
C h a p te r 5 Features and Specifications T e c h n i c al F u n c ti o n al O v e r v ie w Figure 5–1 AMP1-MADIe Block Diagram Channel Volume / Menu Master Volume Channel Select Channel Select Balance Select Preset & Chan Assign Menus Graphics Processor Input Select BNC Input MADI I/O Reclocked Optical Output Reclocked BNC Output MADI Transceiver Conversion Optical Input 64 Programming & Configuration Ethernet UI / System Configuration and Control USB MADI Reclocker Power / Status Left
APPENDIX A Connecting the AMP1-MADIe to a LAN Introduction Overview This chapter describes how to connect your PC to your AMP1-MADIe through a local area network (LAN) and to configure the monitor using the graphical user interface (GUI) on a PC.
A p p e n d i x A C o n n e ct i n g th e A M P 1 -M A D I e t o a L A N Requirements Requirements • You must have a PC or laptop that: • Is running Windows XP, Vista, or Windows 7, • Is connected to a LAN, and • Has access to the Internet.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN I n s t a ll i n g th e AM P 1 - M A D I e M a n a g e r 3. Once you have successfully logged into the Wohler web site, click Products from the home page menu bar. A. Move the cursor down the menu to highlight Audio. B. Then move the cursor to the sub-menu to highlight MADI. C. Finally, move the cursor to the right to click on AMP1-MADIe. When the monitor’s web page displays, click on the Downloads tab in the middle of the page. 4.
A p p e n d i x A C o n n e ct i n g th e A M P 1 -M A D I e t o a L A N Launching the AMP1-MADIe Manager Launching the AMP1-MADIe Manager 1. Launch the AMP1-MADIe Manager from the Desktop. When the AMP1-MADIe Manager appears, it will display the Channels tab by default. Figure A–1 AMP1-MADIe Manager Channels Tab . Wohler AMP1-MADIe Manager v01.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN A d d i n g Y o u r A M P 1 -M A D I e t o Y o u r Ne tw o r k Figure A–2 AMP1-MADIe Manager Ethernet Tab Wohler AMP1-MADIe Manager v01.
A p p e n d i x A C o n n e ct i n g th e A M P 1 -M A D I e t o a L A N Adding Your AMP1-MADIe to Your Network Figure A–3 Configure AMP1-MADIe IP Address Dialog Configure AMP1-MADIe IP Address Use DHCP Direct Connect IP Address 0.0.0.0 IP Mask 0.0.0.0 Unit Name Master Control 3 Update 5. When the Configure AMP1-MADIe IP Address dialog displays, do the following: A. I m p o rt a n t : I m p o rt a n t : Click the Use DHCP check box (if needed) to select DHCP.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN A d d i n g Y o u r A M P 1 -M A D I e t o Y o u r Ne tw o r k 6. Click Refresh. After the system polls the network, all the AMP1-MADIes on the network will display in the Units Responding box. 7. In the event that the AMP1-MADIe you’re looking for does not appear in the AMP1-MADIe Units box, click Locate IP to display the following dialog so you can enter the IP address of the AMP1-MADIe unit you’re looking for.
A p p e n d i x A C o n n e ct i n g th e A M P 1 -M A D I e t o a L A N Disconnecting From an AMP1-MADIe Disconnecting From an AMP1-MADIe Should you need to unselect an AMP1-MADIe to prevent making further configuration changes, you can either select a different unit, or click Disconnect from Remote Unit. 60 821091: A M P 1 - M A D I e U se r Gu i d e © 2 0 1 2 Wo h l e r Tec h n o l o g i e s , I n c. A l l r i g h t s r e s er ve d .
APPENDIX B Software Upgrades Introduction Overview This chapter describes how to download software upgrades to your PC and then transfer and install them to your AMP1-MADIe. I m p o rt a n t : If you have not yet installed the AMP1-MADIe Manager setup software into your PC and connected it to the AMP1-MADIe, you must complete all the steps in Appendix A before continuing.
Appendix B Software Upgrades C h e ck i n g f o r U p d a t e s Checking for Updates Before establishing the connection to the AMP1-MADIe, you should check to see if any software updates are currently available. 1. Launch the AMP1-MADIe Manager from your PC’s desktop. 2. Click the Ethernet tab. Figure B–1 AMP1-MADIe Manager SDI Ethernet Screen Wohler AMP1-MADIe Manager v01.
A p p e n d i x B Software Upgrades C h e c k i n g fo r U p d a t e s B. In the event the system discovers updates to the AMP1-MADIe firmware stored on your hard drive, the system will update the unit and display the dialog shown in Figure B–3 below. Figure B–3 FTP Success Dialog Update Complete! OK Note: In the event the system informs you that an updated version of the AMP1-MADIe Manager is available, you must go to the Wohler web site and download the application.
Appendix B Software Upgrades Upgrading the AMP1-MADIe Upgrading the AMP1-MADIe Figure B–4 AMP1-MADIe Manager SDI Ethernet Screen Wohler AMP1-MADIe Manager v01.