48
Ch apt er 4 In te rn a l M e n u Sy st e m
Met er T yp e an d R e f er e nc e Me n u
rotate the Channel Volume knob to adjust the screen brightness.
Thirty-two adjustment steps are provided for each screen from very
dim to bright to compensate for dimly or brightly lit rooms. The
actual brightness of each screen will change as the control is turned.
The default brightness for both screens is 22.
Screen Saver: Pressing this button and then rotating the Channel
Volume knob selects the screen saver time out. Select values from 5
minutes to 119 minutes (in 1-minute increments) and from 2 hours
to 24 hours (in 1-hour increments). The default setting is 8 hours.
If the AMP1-MADIe is in operation for the screen saver time out
period and no front panel controls have been turned or pressed, the
screens will dim by a certain amount. If double the screen saver
time out period elapses without any front panel control activity, the
screens will dim further. Operating any button or control will
instantly brighten the screens.
BNC: Pressing this button selects the BNC input as the MADI
source. The system will reclock the signal and feed it to both the
BNC and fiber outputs.
Fiber: Pressing this button selects the fiber optical input as the
MADI source. The system will reclock the signal and then feed it to
both the optical output and to the BNC output.
Reclocking: The reclock option can be used to extend the operation
of the unit in cases where a long cable is used before the unit, or a
large number units are attached in series before the unit. Pressing
this button toggles between On and Off. The reclocking feature is
turned off by default and allows you to specify whether the BNC or
optical signals that pass through the AMP1-MADIe are to be
regenerated (Off) or reclocked (On). If the source of the MADI
signal is connected with a long cable or fiber, reclocking will
improve the signal as it passes through. If short cables are used,
regeneration only allows more units to be connected in series.
Meter Type and Reference Menu
The Meter Type and Reference Menu allows you to define the level
meter scale, float, bar and reference.
Note:
Operating the unit with lower brightness settings and
smaller screen saver timeout values will prolong the life
of the displays.