AMP1-MADIe • AMP1-MADIe-SM • AMP1-MADIe-MM 1RU, 8 of 64 Channel, MADI Audio Monitor User Guide (Software Release: V3.
© 2013 Wohler Technologies, Inc. All rights reserved. This publication is protected by federal copyright law. No part of this publication may be copied or distributed, stored in a retrieval system, or translated into any human or computer language in any form or by any means electronic, mechanical, manual, magnetic, or otherwise, or disclosed to third parties without the express written permission of Wohler Technologies. Reproduction Licensed users and authorized distributors of Wohler Technologies, Inc.
Table of Contents Chapter 1. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Introduction ...................................................................1 Overview..................................................................1 Topics ......................................................................1 Safety ...........................................................................2 Instructions ..............................................................
Using and Defining Presets .............................................14 Default Presets........................................................14 Selecting Any Eight Channels ....................................15 Adjusting Channel Select Modes and Channel Volume .........16 Adjusting the Speaker Audio Tone Controls .......................17 Selecting the Optical Input..............................................18 Using the Balanced Analog Outputs..................................
Display and Metering ...............................................34 Level Meters ..................................................... 34 Metering Mode .................................................. 35 Screen Brightness.............................................. 35 Control .................................................................. 35 Channel Select .................................................. 35 Functions Enabled.............................................. 36 Speaker Mute..........
Meter Type and Reference Menu ......................................48 Meter Segment Menu .....................................................50 Version and Ethernet Menu .............................................51 Chapter 5. Features and Specifications . . . . . . . . . . . . . . 53 Introduction..................................................................53 Overview ................................................................53 Topics .........................................................
CHAPTER 1 Installation Introduction Overview The AMP1-MADIe-SM and AMP1-MADIe-MM are 1RU, 8 of 64 channel MADI audio monitors. Each contains a BNC MADI input and output plus (depending upon the model purchased) either a singlemode or a multi-mode fiber input and output. Although the AMP1MADIe-SM (single-mode fiber) and AMP1-MADIe-MM (multi-mode fiber) are distinct models, largely their operation is identical, so they will be referred to in this manual as simply AMP1-MADIe. This unit comes with two 2.
C h a p t e r 1 In s t a l la t i on Sa f e t y Safety Instructions IMPORTANT: 1. Read, keep, and follow all of these instructions; heed all warnings. 2. Do not use this equipment near water. 3. Use only a dry cloth to clean the equipment. 4. Do not block any ventilation openings. 5. Do not install near any heat source such as a radiator, heat register, amplifier, or stove. 6. Do not attempt to plug the unit into a two-blade outlet (with only two prongs of equal width).
C ha p t e r 1 Installation S a f et y Safety Symbols WARNING: The symbol to the left warns of electric shock hazard inside the unit. Disconnect the power cord before removing access panels when installing upgrades. Only qualified service personnel are to operate the equipment with covers removed, and are to exercise caution to avoid personal injury. Mounting The unit is designed for a standard 19" rack.
C h a p t e r 1 In s t a l la t i on C o m p l ia n c e weather-stripping between the vibrating surfaces. Tie loose cables securely with cable ties. Mechanical Bracing The 1RU chassis is securely attached to the front panel. In addition, the chassis has mounting tabs through which you attach it to the rack rail. This feature will reduce or eliminate rear bracing requirements in many mobile/portable applications. The weight of internal components is distributed fairly evenly around the unit.
C ha p t e r 1 Installation F r o n t P a n el frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. ICES-003 This Class A digital apparatus complies with Canadian ICES-003.
C h a p t e r 1 In s t a l la t i on F r o nt P a n el • Power Indicator: This tri-color LED indicates power and basic status information. See Table 1–1 below. Table 1–1 Power Color/Indication Descriptions LED Color Description Steady Green: The AMP1-MADIe is functioning normally. Green Flashing Green: The unit is waiting for an update either via a USB stick or over the Ethernet connection.
C ha p t e r 1 Installation R e a r P a ne l • Select Preset: Presets are complete configurations of monitoring channels, including individual channel volume levels. Pressing this button displays the Preset Selection Menu. • Channel Assign: Pressing this button displays the Channel Assignment Menu in which you can select the exact eight (of the 64) MADI channels you want to monitor. Note that the channels you monitor need not be contiguous.
C h a p t e r 1 In s t a l la t i on M a i n S cr e e n another. Lastly, it can be used to update the AMP1-MADIe software and firmware. Refer to Chapter 3, Appendix A, and Appendix B for details. • Analog Outputs: These male XLR connectors provide three balanced analog outputs: Left, Mono Mix, and Right. The source of these signals is the mix of audio monitored by the internal speakers.
C ha p t e r 1 Installation M ai n S c re e n • Channel Icons: These indicators identify the channel number and the status of the channel. Refer to Table 1–2 on page 9 for the channel legend. Table 1–2 Channel Left Right Center Channel Icon Descriptions Unmuted Muted 1 2 3 1 2 3 • Level Meters: You can monitor and display meters for any eight channels in the MADI input signal. When a channel is muted, the system replaces the level meter with a thin line indicating the channel is muted.
CHAPTER 2 Operation Introduction Overview This chapter describes how to operate the AMP1-MADIe’s Main Screen and how to transfer configuration files to/from a flash drive.
C h a p t e r 2 O p e r a t i on I ni t ia l O p e r a t io n Initial Operation When you first power your AMP1-MADIe, it will be ready to monitor the first eight MADI channels from the BNC input. Turning up the Master Volume will let you hear all eight channels at once. By default, the odd-numbered channels will sound in the left speaker, and the even-numbered channels will sound in the right speaker. Chances are that you will want to change this operation to better suit your needs.
C h a p t e r 2 Operation M on i t o r C h a n n el S e le c t io n Quick Selection If you need to mute and unmute channels frequently, use the Quick setting. It shortcuts the mute/unmute action, while still allowing you to adjust the channel volume when necessary. 1. Press and hold the Channel Select button(s) for one second to highlight one or more channels to adjust. 2. Turn the Channel Volume knob to adjust the volume of the highlighted channel(s). 3.
C h a p t e r 2 O p e r a t i on U s in g a nd D e fi n in g P r e s et s 1. Press the Channel Select buttons of the channels whose volume you want to mute or adjust. 2. Press the Channel Volume knob to mute or unmute the highlighted channels. 3. Turn the Channel Volume knob to adjust the volume of highlighted channels. Using and Defining Presets Default Presets By default, the eight presets in the AMP1-MADIe are set to monitor the 64 MADI channels as shown in Table 2–1 below.
C h a p t e r 2 Operation U s in g a n d D e f in in g Pr e s e t s Figure 2–2 Preset Selection Menu Preset Selection Preset 1 Master Control Select a Preset to save or recall. Preset 5 Default 5 Preset 2 Truck 1 Preset 6 Default 6 Preset 3 Truck 2 To exit without changing anything, press Preset Select again.
C h a p t e r 2 O p e r a t i on A d ju s t i n g C ha n n e l Se l ec t M o d e s a n d C h a n n el V o lu m e Figure 2–4 Channel Assignment Menu Channel Assignment Menu PCR1-AD Bob 1 1 1 PCR2-DIR Bucky 31 31 31 PCR1-GFX Phil 2 2 PCR3-PGM 2 Press Channel Volume to assign Left, Right, or Center. L 64 64 64 Turn Channel Volume to pick a MADI channel. 5 REM-24 NVG/NYJ 23 23 23 REM-12 LONDON 11 11 11 ANNC-12 Costas 17 17 17 TAPE-SUP Dave 5 5 R C Press Chan Assign to exit.
C h a p t e r 2 Operation A d j u s t i ng t h e S p e a k e r A u d io T o n e C o n t r o ls • Quick: Used when it is more likely necessary to mute or unmute channels quickly, with a one-touch operation. Pressing the audio Channel Select button in Audio Menu 2 selects between the three possible modes of operation for the Channel Select buttons on the Main Screen. 1. To adjust these controls, hold the Channel Volume knob for at least three seconds until Audio Menu 1 displays. 2.
C h a p t e r 2 O p e r a t i on Se l e ct i n g t h e O p t i c a l I n p u t Figure 2–5 Audio Menu 2 Audio Menu 2 Flat Tone Controls Flat response, tone controls set to 0 dB Bass 0 dB Treble 0 dB Back 4 ms Audio Delay Low Cut Off The Tone Controls affect the speaker sound only. Press and hold Channel Single Multiple Quick Audio Chan. Select Next Volume to exit menu.
C h a p t e r 2 Operation U s in g t h e B a la n c ed A na l o g O u t p u t s 2. Press the Next button several times until the Options Menu appears.. Figure 2–6 Options Menu Screen Bright Screen Saver Options Menu Left Right 22 22 Press to select, then turn Channel Volume to adjust. 8 hrs MADI Input Coax Copper Input BNC Single-Mode Fiber Input Fiber ON Back Next Press and hold Channel 3. Reclocking Volume to exit menu. Press either BNC or Fiber.
C h a p t e r 2 O p e r a t i on Pr e F a d e o r P o s t F a d e M et er i ng Figure 2–7 Audio Menu 1 Audio Menu 1 Never Mute Mute with Headphone Speaker Mute Analog Outputs Not even when headphones are plugged in Fixed Level, Mute Controlled Whenever headphones are plugged in Master Volume/Balance Controlled Always Mute Audio may only be monitored from analog outputs or headphones Channel Volume Controlled Back Fixed Master Volume Channel Volume Next To quickly exit Menus, press Channel Vo
C h a p t e r 2 Operation S a v in g Y o ur Se t t i n g s Press the Metering Mode button to change between Post Fade and Pre Fade. Then press the Back or Next buttons several times to exit to the Main Screen. Saving Your Settings Once you have set up your AMP1-MADIe exactly the way you want it, you will probably want to save the settings for a quick recall, just in case someone else accidentally disturbs them. To do this, simply press the Select Preset button.
C h a p t e r 2 O p e r a t i on U SB Po r t F u n ct i o na l it y USB Port Functionality You can copy configuration files to and from your unit by using a flash drive connected to the USB port. You can also use a flash drive to update the software in the AMP1-MADIe. Refer to Appendix B for instructions. Immediately after connecting the flash drive to your AMP1-MADIe, the Flash Drive Connected screen displays (interrupting any current functions except an Ethernet connection) as shown in Figure 2–12 below.
C h a p t e r 2 Operation U S B P or t F u n ct io n a lit y Copying a Configuration to the AMP1-MADIe 1. To load a configuration file to the AMP1-MADIe from your flash drive, press Get. The Get a setup from the Flash Drive screen will display as shown in Figure 2–13 below. The files that exist on the flash drive will be lit in bright green. Figure 2–13 Get a Setup From the Flash Drive Screen Get a setup from the Flash Drive File 1 File 2 File 3 File 4 2.
C h a p t e r 2 O p e r a t i on Update Menu Figure 2–14 Save to Flash Drive Screen Save to Flash Drive File 1 12345678901234567890 File 2 File 3 File 5 Select the Flash Drive file number 1 to 7 in which to save the current configuration of this AMP1-MADIe File 4 File 6 File 7 To exit without saving, press Cancel/Quit Cancel/Quit 2. The bright blue choices indicate files that already exist.
C h a p t e r 2 Operation M e nu Lo c k o ut O v e rr i d e pressing both the Select Preset button and the Channel Assignment buttons for three seconds or more to display the Menu Lockout Override screen as shown Figure 2–15 below. Figure 2–15 Menu Lockout Override Screen Menu Lockout Override Menu System Select Preset Select which menu you would like to access. Channel Assign Cancel • Menu System: Press this button to enter the menu system.
CHAPTER 3 AMP1-MADIe Graphical User Interface (GUI) Manager Introduction Overview This chapter describes how to use the AMP1-MADIe Manager to the configure the AMP1-MADIe. I m p or t a n t : If you have not yet installed the AMP1-MADIe Manager setup software on your PC and connected it to the AMP1-MADIe, you must complete all the steps in Appendix A on page 59 before continuing.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Ru n n in g t h e A M P 1 - M A D I e M a n a g er Running the AMP1-MADIe Manager The AMP1-MADIe Manager allows you to customize the monitor’s configuration to perfectly suit your needs.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e C h a n n el s T a b • Open from PC: Clicking this button displays the Windows Open dialog so you can open a configuration file on your PC. • Send to Unit: Clicking this button sends a setup overwriting AMP1-MADIe’s current configuration (including options and presets). This AMP1-MADIe will then automatically be set to the configuration saved in Preset 1.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e P r e s et T a b s The Preset Tabs Since all the Preset tabs are identical we will only show the first one to explain the settings it provides for each preset. Figure 3–3 Preset 1 Tab Wohler AMP1-MADIe Manager v01.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e C u r r e nt T a b • Channel Number: Click the drop-down menu to select the MADI channel (1 through 64) you want to monitor in this position. • Speaker Assignment: Click the drop-down menu to select the speaker(s) you want to hear this channel in: Left, Center (both), or Right. The Channel Assignment icon will change accordingly.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e C u rr e n t T a b Figure 3–4 Current Preset Tab Wohler AMP1-MADIe Manager v01.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e F a c il it y T a b The Facility Tab Figure 3–5 Facility Tab Wohler AMP1-MADIe Manager v01.00 Channels Preset Preset1 1 Preset 2 Preset 3 Preset 4 Preset 5 Preset 6 Preset 7 Preset 8 Current Facility Options Ethernet USB Facility Configuration Save Facility Configuration Save the current settings, including all Channel settings, Options and all 8 Presets to the Facility Configuration file.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e O p t i o ns Ta b The Options Tab Figure 3–6 Options Screen Wohler AMP1-MADIe Manager v01.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e O p t io n s T a b Metering Mode Metering Mode: Click to select either Pre Fade or Post Fade. • Pre Fade: Meters show the levels before the channel volumes are applied to the input signals. • Post Fade: (Default) Meters show the levels after the channels are applied to the input signals. Screen Brightness Select the screen brightness for each screen and the duration for the screen saver.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e O p t i o ns Ta b • Multiple: For use in situations where changes are predominantly made on more than one channel at a time. • Quick: For use in situations where channels need to be frequently muted or unmuted. Functions Enabled These controls allow you to lock operators out of these key functions if you do not want them changing these settings.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager T h e O p t io n s T a b Audio Delay This control can be used to adjust the lip sync between the MADIe and a video monitor. Click either No Delay, or click the up or down arrows to either increase or decrease the amount of audio delay time from 0 (default) to 170 ms in 1 ms increments. Tone Controls • Flat: (default) For a flat speaker response, click Flat. • Bass and Treble: Press the Flat button to enable the Bass and Treble controls.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e E t h e r ne t Ta b • Master Volume Controlled: The volume of the outputs is controlled by the Volume and Balance knobs on the front panel. Note: The Analog Output can be both Channel Volume Controlled and Master Volume Controlled. The Ethernet Tab Figure 3–7 Ethernet Tab Wohler AMP1-MADIe Manager v01.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager Th e Et h e r n et T a b File Update Options Before beginning any update procedure, click either Update as Needed or Update All. • Update as Needed should be used for most updates. • Update All should only be used at the direction of a tech support representative. Note: To continue with a software upgrade, refer to Appendix B on page 67.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e E t h e r ne t Ta b administrator. Checking this option will disable the other IP entry fields. Use the IP Address, IP Mask, and Gateway fields to configure a static IP connection with a LAN or with a PC connected directly to the unit.
C ha p t e r 3 AMP1-MADIe Graphical User Interface (GUI) Manager The USB Tab The USB Tab Using a Flash Drive You can use a USB flash drive to transfer settings from one AMP1-MADIe to another, and to or from any Windows computer. This tab allows you to save or retrieve files from a USB flash drive attached to the host computer. Note: To use the USB port from the AMP1-MADIe menu system, refer to USB Port Functionality on page 22. Figure 3–8 AMP1-MADIe Manager USB Screen Wohler AMP1-MADIe Manager v01.
C h a p t e r 3 A M P1 - M A D I e G r a p h i ca l U s e r I n t e r fa c e ( G U I ) M a na g e r Th e U S B T a b flash drive file is not selected. The system will only read the files from the \Wohler folder on the flash drive. • Rename: To rename a configuration file, click on the filename you want to rename and then click Rename. When the dialog displays, rename the file and click Save.
CHAPTER 4 Internal Menu System Introduction Overview This chapter provides an in-depth description of all the features, specifications, and menus and all their respective options and functions. I m p or t a n t : The AMP1-MADIe local menus cannot be used at the same time that the PC setup software is connected. If this happens, the PC setup software will take precedence and display the words Remote Access notifying you about the PC connection.
C h a p t e r 4 In t e r n a l M e n u S y s t e m M e n u N a v ig a t io n O v e r v ie w Menu Navigation Overview You can launch the menu system by pressing and holding the Channel Volume knob for three seconds. Navigate the menu tree with the Back and Next buttons at the bottom of each screen.
C h a p t e r 4 Internal Menu System A u d io M e n u 1 • Back: Pressing this button closes this menu and opens the previous menu, one step up the menu tree. • Next: Pressing this button closes this menu and opens the next menu, one step down the menu tree. • Pressing a menu setting button will light the button name in yellow if it requires the use of the yellow Channel Volume control for its adjustment. Audio Menu 1 This menu allows adjustment of various audio related settings.
C h a p t e r 4 In t e r n a l M e n u S y s t e m A u d i o M en u 2 • Fixed: Pressing this button prevents the Master Volume and Channel Volume controls from affecting the analog outputs. They will output all unmuted channels at a fixed line level. • Master Volume: Pressing this button enables the Master Volume and Balance controls to affect the analog outputs. This setting can be convenient to use when monitoring is always done through the analog outputs with external amplifiers and speakers.
C h a p t e r 4 Internal Menu System O p t i o ns M e n u • Bass: Pressing this button and then turning the Channel Volume knob adjusts the bass response up or down in 2 dB steps to as low as -12 dB or as high as +12 dB. Pressing Bass a second time moves the highlight to the Low Cut setting. Pressing the Channel Volume knob turns low cut on or off. When it is turned on, an additional low-cut filter is engaged.
C h a p t e r 4 In t e r n a l M e n u S y s t e m M e t e r T y p e a n d R e f er e n c e M e n u rotate the Channel Volume knob to adjust the screen brightness. Thirty-two adjustment steps are provided for each screen from very dim to bright to compensate for dimly or brightly lit rooms. The actual brightness of each screen will change as the control is turned. The default brightness for both screens is 22.
C h a p t e r 4 Internal Menu System M e t e r T y p e a n d R e f er e n c e M e n u Figure 4–5 Meter Type and Reference Menu Meter Type & Reference Menu Scale AES 0 -10 0 dBr = 0 dBFS Press any key to select, and turn Channel Volume to adjust. Metering Mode toggles between pre-fade and post-fade. -20 Float IEC1 -30 Bar VU Reference -40 -50 -60 Post Fade Metering Mode Pre Fade Back Next Press and hold Channel Volume to exit menu.
C h a p t e r 4 In t e r n a l M e n u S y s t e m M e t e r S e g m en t M e n u • Bar: Pressing this button and then rotating the Channel Volume knob steps through the available settings for the bar ballistics. Refer to Table 4–1 on page 49. • Reference: Pressing this button and then rotating the Channel Volume knob adjusts the reference. Refer to Table 4–1 on page 49 for the reference standards for each scale.
C h a p t e r 4 Internal Menu System V e r si o n a n d E t h e r ne t M e n u • Middle Segment: Pressing this button and then rotating the Channel Volume knob adjusts the division between the middle and lower segments. You can adjust the color boundary in one dBr increments, and it has the same range as the bottom and top limits of the meter. • Default: Pressing this button changes the settings on this menu and on the Meter Type and Reference Menu back to the factory settings for the chosen scale type.
C h a p t e r 4 In t e r n a l M e n u S y s t e m V e rs i on a n d E t h e rn e t M e n u • Factory Default: Pressing this button opens a cautionary window to verify that you really want to restore the AMP1-MADIe setup to the factory default. If you press the Factory Default button again, the action proceeds and the unit will restart. Otherwise, after five seconds, the factory default request is cancelled. You can also cancel the factory default request by pressing any other button.
CHAPTER 5 Features and Specifications Introduction Overview This chapter lists the features and specifications. Topics Topics Introduction Page 53 Features 54 Specifications 55 Technical Functional Overview 57 82 10 91 : A MP 1- MA D I e U se r G u id e © 2 0 1 3 Wo hl e r Te c hno lo g i e s, In c. A ll r ig h ts re se r v ed .
C h a p t e r 5 F e a t u re s a nd S p e c if ic a t io n s F e a t u r es Features • Totally digital system architecture with high fidelity Class D amplifiers • Coax MADI input and output with passive power fail bypass • Optical MADI I/O • Regenerated or reclocked BNC coax and Optical MADI outputs • Models available with either multi-mode or single-mode optical MADI inputs/outputs • Automatic format conversion from coax to optical or optical to coax.
C ha p t e r 5 Features and Specifications S p e ci f ic a t io n s • Easy update and management software • Shallow chassis depth (4.25”) • IEC power input, 100 – 240 VAC +/- 10%, 50/60 Hz Specifications Table 5–1 Specifications Specification Power requirements Power consumption Dimensions (H x W x D) Weight Space Required Supplied Accessories Display Type Number of Displays Screen Size Screen Resolution Sample Rate De-Multiplexing Inputs Values/Domains 100 V to 240 V AC ± 10%, 50/60Hz 60 Watts 1.
C h a p t e r 5 F e a t u re s a nd S p e c if ic a t io n s Sp e ci fi ca t io n s Table 5–1 Specifications (Continued) Specification Outputs Values/Domains • Multi-Mode Fiber: 1 MADI Optical SC-Connector, 1300nm or Single-Mode Fiber: 1 MADI Optical SC Connector, 1310nm • 1 reclocked MADI BNC • 1 headphone (1/4” jack) Cable/Fiber Length (max) Level Meters Analog Output Frequency Response Analog Output Distortion Analog Output Dynamic Range Analog Output Reference Level Speaker Bass and Treble Tone C
C ha p t e r 5 Features and Specifications Te c h n ic a l F u nc t i on a l O v e rv ie w Table 5–1 Specifications (Continued) Specification Values/Domains Selectable: • Meter thresholds, Level Meter Characteristics • Reference, • Segment Colors, and Peak Acoustic Output Power Output RMS Acoustic Frequency Response • Ballistics 90dB SPL (@ 2 feet) 6 Watts RMS, 12 Watts peak (each side) 150 Hz to 16 kHz (± 5 dB) Technical Functional Overview Figure 5–1 on page 58 illustrates the overall functionali
58 A MP 1- MA D Ie U se r G u id e AMP1-MADIe Block Diagram © 2 01 3 Wo hle r Te ch no lo g ie s, In c. A l l ri g ht s re s e r v ed .
APPENDIX A Connecting the AMP1-MADIe to a LAN Introduction Overview This chapter describes how to connect your PC to your AMP1-MADIe through a local area network (LAN) and to configure the monitor using the graphical user interface (GUI) on a PC.
A p p e nd ix A C o nn e c t in g t h e A M P 1 - M A D Ie t o a L A N Re q ui r em e nt s Requirements • You must have a PC or laptop that: • Is running Windows XP or Windows 7, • Is connected to a LAN, and • Has access to the Internet.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN I n s t a ll in g t he A M P 1- M A DI e M a n a g e r 3. 4. Once you have successfully logged into the Wohler web site, click Products from the home page menu bar. A. Move the cursor down the menu to highlight Audio. B. Then move the cursor to the sub-menu to highlight MADI. C. Finally, move the cursor to the right to click on AMP1-MADIe. When the monitor’s web page displays, click on the Downloads tab in the middle of the page.
A p p e nd ix A C o nn e c t in g t h e A M P 1 - M A D Ie t o a L A N L a un c h in g t h e A M P 1- M A DI e M a n a g e r Launching the AMP1-MADIe Manager 1. Launch the AMP1-MADIe Manager from the Desktop. When the AMP1-MADIe Manager appears, it will display the Channels tab by default. Figure A–1 AMP1-MADIe Manager Channels Tab . Wohler AMP1-MADIe Manager v01.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN A d d i n g Y o u r A M P 1 - M A D I e t o Y o ur N e t w o r k Figure A–2 AMP1-MADIe Manager Ethernet Tab Wohler AMP1-MADIe Manager v01.
A p p e nd ix A C o nn e c t in g t h e A M P 1 - M A D Ie t o a L A N A d d in g Y ou r A M P1 - M A D I e t o Yo u r N e t w or k Figure A–3 Configure AMP1-MADIe IP Address Dialog Configure AMP1-MADIe IP Address Use DHCP Direct Connect IP Address 0.0.0.0 IP Mask 0.0.0.0 Gateway 0.0.0.0 Unit Name Master Control 3 Update 5. When the Configure AMP1-MADIe IP Address dialog displays, do the following: A. I m p or t a n t : Cancel Click the Use DHCP check box to select DHCP.
A p p e n d i x A Connecting the AMP1-MADIe to a LAN A d d i n g Y o u r A M P 1 - M A D I e t o Y o ur N e t w o r k E. Click OK to close the dialog. Note: To change the IP settings, the unit must restart. The Windows application will automatically restart the unit, and display the unit with its new address after it has rebooted. This takes approximately 10 seconds. 6. Click Refresh. After the system polls the network, all the AMP1-MADIes on the network will display in the Units Responding box. 7.
A p p e nd ix A C o nn e c t in g t h e A M P 1 - M A D Ie t o a L A N Di s co n n e ct i n g F ro m a n A M P 1 - M A D I e C. I m p or t a n t : Click Find. You must see your AMP1-MADIe listed in the AMP1-MADIe Units area. If not, double-check your connections. If the monitor still does not display, call Wohler’s technical assistance. (See Wohler’s contact into on page ii.) 8. If the monitor does not automatically show up in the AMP1-MADIe Units area, click the Refresh button.
APPENDIX B Software Upgrades Introduction Overview This chapter describes how to download software upgrades to your PC and then transfer and install them to your AMP1-MADIe. I m p or t a n t : If you have not yet installed the AMP1-MADIe Manager setup software into your PC and connected it to the AMP1-MADIe, you must complete all the steps in Appendix A before continuing. The two software upgrade methods include: 1. Using a USB flash drive. 2. Using the AMP1-MADIe Manager over Ethernet.
A p p e nd ix B S of t w a r e U p g r a d e s U p g r a d i n g t h e So f t w a r e U s in g a U S B F l a s h D ri v e Upgrading the Software Using a USB Flash Drive I m p or t a n t : If you have not already done so, place a software update onto the flash drive using the instructions in Programming Files on page 42. USB software updates can only be performed if the unit has firmware version 3.00 or later. Earlier versions must be updated using the Ethernet port.
A p p e nd ix B Software Upgrades U p g r a d i n g t h e S o f t w a r e U s in g a U S B F l a s h D ri v e (Optional) Before updating the software in the AMP1-MADIe, you may want to compare the versions already installed versus the new version in the software update. Pressing the View Versions button displays the Software Update Versions screen shown in Figure B–3 below. To abort the process, press the Cancel/Quit button to cancel the update request and return to the Flash Drive Connected menu instead.
A p p e nd ix B S of t w a r e U p g r a d e s U p g r a d i n g t h e So f t w a r e U s in g a U S B F l a s h D ri v e A. Press the Update Software as Needed button to install only newer software versions contained in the flash drive into the AMP1-MADIe. The next screen to appear will describe what to expect in the installation process. B.
A p p e nd ix B Software Upgrades U p g r a d in g t h e A M P 1 - M A D Ie O v e r Et he r n e t Upgrading the AMP1-MADIe Over Ethernet Checking for Updates Before establishing the connection to the AMP1-MADIe, you should check to see if any software updates are currently available. 1. Launch the AMP1-MADIe Manager from your PC’s desktop. 2. Click the Ethernet tab. Figure B–6 AMP1-MADIe Manager SDI Ethernet Screen Wohler AMP1-MADIe Manager v01.
A p p e nd ix B S of t w a r e U p g r a d e s U p g r a d i n g t h e A M P1 - M A D I e O v e r E t h e rn e t Figure B–7 No Updates Dialog No updates were needed OK B. In the event the system discovers updates to the AMP1-MADIe firmware stored on your hard drive, the system will update the unit and display the dialog shown in Figure B–8 below.
A p p e nd ix B Software Upgrades U p g r a d in g t h e A M P 1 - M A D Ie O v e r Et he r n e t Performing the Upgrade Figure B–9 AMP1-MADIe Manager SDI Ethernet Screen Wohler AMP1-MADIe Manager v01.
A p p e nd ix B S of t w a r e U p g r a d e s U p g r a d i n g t h e A M P1 - M A D I e v ia a Di r e ct C o n ne c t i on Upgrading the AMP1-MADIe via a Direct Connection A direct connection should only be used when a LAN (local area network) is not available or is not connected to the unit. A direct connection to any unit can be tricky if you're not familiar with setting static IP addresses. Fortunately, this unit has a DHCP server embedded in it, which will make a direct connection much easier.
A p p e nd ix B Software Upgrades U p g r a d i ng t h e A M P 1 - M A D I e v i a a D i re c t C o nn e c t io n 5. Turn the unit on, and set the unit for direct mode and DHCP. This can be done in the Version and Ethernet Menu, Connect: Direct. Note: You might want to write down the values for the IP Address, IP Mask, and Gateway so you can reset them later.
A p p e nd ix B S of t w a r e U p g r a d e s U p g r a d i n g t h e A M P1 - M A D I e v ia a Di r e ct C o n ne c t i on Of course, if you are familiar with setting compatible static IP addresses and subnets in both your host computer and the MADIe, that option is open to you as well, and again, you can use either an Ethernet patch cable or a crossover cable. I m p or t a n t : 8 21 09 1 : 76 This concludes the AMP1-MADIe direct connection procedure.