User guide
82 10 1 6: AM Px- E8 Ser ie s U se r G u ide
© 2013 Wohl er Tec hn ologi e s , In c . Al l r ig h ts re se rved.
11
Ch ap t er 2 System Overview
F ron t Pa n e l Co n t ro ls
• Input Lock Status (Digital Inputs Only): Displayed in the center of
bottom line, the Input Lock Status shows the lock status of the
selected digital input(s). If any input channel pairs are not locked,
then they will display as short dashes. Each dash (-) indicates a
position for displaying the channel pairs available for monitoring
from left to right: 1/2, 3/4, 5/6 and 7/8. The unit updates the Input
Lock Status whenever it detects a signal change.
See Figure 2–3 below through Figure 2–6 on page 12 for additional
examples.
Figure 2–3 Status Display Example: Standard Input
Source - SD-SDI Input 2
Figure 2–4 Status Display Example: Standard Input
Source - HD-SDI Input 1
DM3 SD.SDI2 DM3
1 3 5 7
2 4 6 8
GP1
GP2
Source Status
(SD-SDI Input 2)
Mix Status
(Downmix 3)
Mix Status
(Downmix 3)
Input Lock Status
(Channels 1 through 8 Locked)
SDI Group
(Group # 2)
SDI Group
(Group # 1)
MIX HD.SDI1 MIX
5 7
- - 6 8
GP3
GP4
Source Status
(HD-SDI Input 1)
Mix Status
(Custom)
Mix Status
(Custom)
Input Lock Status
(Channels 1 through 4 Not Locked;
Channels 5 through 8 Locked)
SDI Group
(Group # 4)
SDI Group
(Group # 3)