User guide

821189: AMP1-16-M User Guide
© 2014 Wohler Technologie s , In c . A l l rights reserve d .
52
Append ix A Connecting the A MP1-16-M to a LAN
Addi ng Your A MP1-16-M to Y ou r Ne two rk
5. When the
Enter AMP1-16-M IP Address
dialog displays, do
the following:
A. Click the
Use DHCP
check box (if needed) to select DHCP
B. Do NOT check
Direct Connect
if connecting to the unit
through a LAN. If you wish to connect to the unit directly,
see Appendix B on page 55.
C. Enter the
Unit IP address.
D. Enter the
Unit IP Mask
E. (Optional) Enter a Unit Name of up to 15 characters. The
name you select for this AMP1-16-M should denote its
position or function within your facility so that it can be easily
recognized later
.
F. Click
Update
to close the dialog. Click
Cancel
to ignore any
changes and return to the previous window. Note: A grayed
Update
button means the IP information is not correct.
To change the IP settings, the unit must restart. The Windows
application will automatically restart the unit, and display the unit
with its new address after it has rebooted. This takes
approximately 10 seconds.
6. Click
Refresh
. After the system polls the network, all the
AMP1-16-Ms on the network will display in the
Units
Responding
box.
7. If the unit is located on a different subnet than the host computer,
the Windows Manager may not be able to automatically locate it.
In this case, use the Locate IP button.
Important:
If your network uses DHCP, then skip Steps C and D and continue on
to Step E below.