User guide
821189: AMP1-16-M User Guide
© 2014 Wohler Technologie s , In c . A l l rights reserve d .
44
Chap ter 5 Fe atur es an d Speci fications
Audi o Forma ts
Audio Formats
All of the audio formats listed in Table 5–2 below are available for
monitoring in the AMP1-16-M.
Level Meter Characteristics
Selectable:
• Meter thresholds,
• Reference,
• Segment Colors, and
• Ballistics
Peak Acoustic Output 90dB SPL (@ 2 feet)
Power Output RMS 6 W RMS, 12 W peak (each side)
Frequency Response 150 Hz to 16 kHz (± 5 dB)
Analog Output Reference
Level
-20 dBFS = +4 ± 1.0 dBu
Analog Output Frequency
Response
40 Hz to 20 kHz (± 1dB)
Analog Output Distortion <0.01% THD+N
Analog Output Dynamic
Range
> 100 dB
SDI Input Termination 75 Ω unbalanced
Hum and Noise Better than -68dB below full output
Electrical Distortion
<0.05% at any level below limit
threshold
Table 5–1 Specifications (Continued)
Specification Values/Domains
Table 5–2 Audio Formats
Standard Format Rate
SD
29.97
25