User guide

821189: AMP1-16-M User Guide
© 2014 Wohler Technologies, I n c . A l l r ights reserve d .
37
Ch apter 4 Internal Menu System
Me te r Seg me nt Me nu
Meter Segment Menu
On the
Meter Segment Menu
, you can customize your level meter
segments thresholds and colors.
Figure 4–7 Meter Segment Menu
Upper Segment
: Pressing this button and then rotating the
Trim
knob adjusts the division between the upper and middle segments.
You can adjust the color boundary in 1 dBr increments, and it has
the same range as the bottom and top limits of the meter.
Middle Segment
: Pressing this button and then rotating the
Trim
knob adjusts the division between the middle and lower segments.
You can adjust the color boundary in 1 dBr increments, and it has
the same range as the bottom and top limits of the meter.
Default
: Pressing this button changes the settings on this menu
and on the
Meter Type and Reference Menu
back to the factory
settings for the chosen scale type.
Upper, Middle, and Lower Color
: Pressing this button and then
rotating the
Trim
knob cycles the upper, middle, or lower color of
the displayed sample level meter color through a wide variety of
colors.
Meter Segment Menu
Set Default
23
19
13
Upper Color
Middle Color
Lower Color
0
-60
-50
-40
-30
-10
-20
-20 dBFS
-30 dBFS
Upper
Segment
Middle
Segment
NextBack
Press a Segment or Color
button and then turn the
Trim control to adjust.
To quickly exit these Menus, press Trim for 3 seconds