Chap ter 4 In te rnal Me nu Sy stem
Me te r Type and Refer en ce Me nu
turn the selected phase indicator
On
or
Off
. When set to
On
, an out
of phase condition for the associated pair will be displayed on the
Main Screen
and when set to
Off
, out of phase conditions for the
associated pair will not be displayed on the
Main Screen
. By
default all phase indicators are enabled.
Volume/Balance
: Pressing this button causes the front panel
knobs to function as
Volume
and
Balance
controls. This is the
default setting.
Left/Right Volume
: Pressing this button causes the front panel
knobs to function as
Left Volume
and
Right Volume
controls.
Meter Type and Reference Menu
The
Meter Type and Reference Menu
allow you to define the level
meter scale, float, bar and reference.
Figure 4–6 Meter Type and Reference Menu
Scale
: Pressing this button and then rotating the
Trim
knob steps
through the scales for the level meters. Six selections are available as
shown in Table 4–1 below.
Meter Type & Reference Menu
Back Next
AES
Single
Scale
Float
0
-60
-50
-40
-30
-10
-20
VUBar
Mono Chan .
Select
Multiple
Audio Pair
Select
0 dBr = 0 dBFS Reference
To quickly exit these Menus Press TRIM for 3 seconds .
Press any key to select , and
turn the Trim control to adjust .
Single
DisableEnable
Table 4–1 Meter Limits and References
Scale
Bottom
Limit
Top Limit
Default
Reference
Default Color
Bounds
Default Ballistics
Lower Upper Float Bar
AES -72 dBFS 0.0 dBFS 0 dBFS = 0 dBFS -30 dBFS -20 dBFS
IEC
Type I
VU
VU -45 dBr +3.5 dBr -20 dBFS = 0 dBr -3 dBr 0 dBr VU