User guide

821189: AMP1-16-M User Guide
© 2014 Wohler Technologie s , In c . A l l rights reserve d .
20
Chap ter 3 AM P1 -16 -M G rap hi ca l U ser Int er fa ce (G UI) Man ager
Th e Op tions Tab
you can click the
Meter Scale Default
button to return to the
default for that scale. The scale itself won't change.
3. Also in the
Level Meters
area, click the up or down arrows to
select the levels at which the colors between the top and middle
segments and the middle and lower segments.
4. Click the up or down arrows to select the colors for each of the
level meter segments.
5. In the
Speaker Mute
area, click to select one of three speaker
configurations:
A.
Never
: Never mute the speakers even when headphones are
connected.
B.
Phones
: Only mute the speakers when the headphones are
connected.
C.
Always
: Always keep the speakers muted. This option may
be useful if you only want to monitor audio externally,
through the XLR audio outputs on the rear panel.
6. In the
Analog Output
area, click to select one of three output
volume options.
Fixed Line Level
is exclusive of the other two:
A.
Fixed Line Level
: The volume of the output is fixed to the
volume of the corresponding inputs.
B.
Volume/Balanced Controlled
: The volume of the outputs
is controlled by the
Volume
and
Balance
knobs on the front
panel.
C.
Trim Controlled
: The analog outputs are controlled by the
Trim
settings.
7. In the
Audio Muting and Delay
area select any combination of
Non-Audio
or
PA Header
.
Note:
Note, if the
Analog Output
is set to controlled and the
Speaker Mute
is set to
Always
, then plugging in the
headphones will cause the analog outputs to mute.
Note:
The AMP1-16-M detects PA headers that represent
encoded data streams.