User guide

821042: RMT-170e Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
14
RMT-170e HD Series User Guide
Front Panel Controls
SDI Input 1/2 (Button/Indicator): This indicator glows green when
this input is selected for display on the monitor. As a control, this
button selects the SDI signal for display to the monitor.
Line 1/2 (Button/Indicator): This indicator glows green when this
input is selected for display on the monitor. As a control, this button
selects the signal for display to the monitor. You can select from
three signal types for Line 2 in the
USER CONFIG menu of the OSD
Menu
.
DVI-I (Button/Indicator): This indicator glows green when this
input is selected for display on the monitor. As a control, this button
selects the signal for display to the monitor. Select from three signal
types in the USER CONFIG menu of the OSD Menu.
Aspect (Button/Indicator): This indicator glows green when a non-
default aspect ratio has been selected for this signal. As a control,
this button toggles between 4:3 and 16:9.
F1 through F6 (Buttons/Indicators): These indicators glow
greenwhen the associated function is active.
Status (Button/Indicator): Pressing this button toggles the status
display (not a menu) on and off to the monitor. If the button is not
pressed a second time, the status will disappear after several
seconds.
OSD Menu Buttons
Menu (Button): Pressing the Menu button displays the OSD menu.
Refer to Using the OSD Menu on page 19 for more details.
Up/Down (Buttons): Pressing these buttons after pressing the
Menu button navigates through the menus and submenus up or
down respectively. Neither of these buttons functions when the
OSD Menu is not displayed on the monitor.
Enter (Button):The Enter button selects menus, submenus, and
option values in the OSD Menu. When the OSD Menu is not
displayed on the monitor, this button displays F1 to F6 functions
assignments.