Operating instructions
11
8H
8G
8
9
6F
6D
6G
8 Take out the frequency converter in the following way:
a) Remove the cover plate (8A) by loosening the screws
(8B).
b) Remove the screws (8C) in the bottom of the mixer.
c) The frequency converter including ttings (8D) and trafo
(8E) can now be lifted backwards out of the mixer.
d) The trafo can be loosened from the frequency converter
by removing the screw (8F).
9
Exchange the fuse by taking out the frequency converter
(8), loosen the screws (8G) and the cover box (8H) can now
be removed.
1
Take off the rear part by removing the 2 screws (1A)
2 The lid of the mixer can be taken off when the rear part (1) has been removed. Push the lid a little backwards,
and lift it free.
3 Take off the operation panel by removing the rubber gasket (3A) and the thumb screw (4A) on the attachment
drive. Remove the nut (3B) and loosen the 2 screws (3C). The screws must still grab the two ttings (3D) which
are to be lifted up together with the screws.
4 Take out the attachment drive by removing the thumb screw (4A), the rubber gasket (3A) and the operation panel
(3). At last loosen the pointed screw (4B)
5 Take off the display print by loosening the screw (5A) and taking off the plastic box (5B). Then loosen the four
screws (5C).
6 Exchange the Poly V-belt in the following way:
a) Take off the rear part of the mixer (1) and the lid (2).
b) Loosen the four screws (6A) holding the motor base (6B). By pushing the base towards the front of the mixer,
the belt will be slackened and can be lifted off the motor pulley (6C) and the planetary head pulley (6D).
c) Mount the new Poly V-belt by pushing if down over the two pulleys.
d) Tighten the Poly V-belt by pushing the motor base towards the back of the mixer. Use a big screw driver or the
like to hold the base while the screws are tightened.
6C The motor pulley can be taken off by removing the locking ring
(6E), and then using a pulling-off device.
6D Take off the planetary head pulley in the following way:
a) Take off the rear part (1), the lid of the mixer (2) and the Poly
V-belt (6).
b) Screw the pointed screws (6F) out of the pulley. The pulley
can now be lifted off the clamping ring.
c) To be able to loosen the clamping ring from the shaft, screw
one of the pointed screws approx. one turn down into the mid-
dle centre hole (6G). The clamping ring can be removed.
7 Take out the motor in the following way:
a) Shut off the power to the mixer, or dismantle the power cable from the connection point.
b) Take off the rear part (1), the lid of the mixer (2), and the Poly V-belt (6).
c) Disconnect the motor cable.
d) Remove the four screws (6A), and the motor base (6B) with motor (7) can now be lifted off the mixer.