Operating instructions

24
6 Conditions of use and installation
The machine operator must arrange for the site preparatory work. This should be carried out by
approved contractors in accordance with general and local regulations.
WMF Customer Service technicians are only permitted to connect up the machine to the prepared
connections. They are not authorised to carry out plumbing or wiring work on site and will not be
responsible for such work.
Rated power 200 Watt
Connecting cable, site supply*
3 × 1.5
2
Fuse, site supply
1 × 16A
Mains voltage tolerance
230 V + 6 % - 10 %
Power cut < 50 ms does not affect machine operation
Ambient temperature
+ 5°C to + 35°C (drain water system in case of frost)
Max. humidity
80 % rel. humidity without dewing, do not spray machine
with water;
do not use machine out of doors.
Installation clearance
For operating, service and safety reasons the machine should
be installed with clearance of not less than 50 mm from the
back and sides of the building or non-WMF components.
A clear height of 1100 mm from the top of the supporting
surface should be ensured. The height of the supporting
surface from the floor surface should be not less than 700 mm
and not more than 900 mm.
If the machine connections are to be routed down through the
counter, remember also to allow space for the connections.
These may restrict the available space below the machine.
* The site electrical system must comply with IEC 364. For greater safety, an earth leakage circuit breaker
with a rated fault current of 30 mA to EN 61008 should be fitted in the supply line to the machine. In the
vicinity of the machine, for a single-phase connection a shockproof socket and for a three-phase connection a
5-pole CEE/CEKON socket to EN 60309 should be fitted. If the power lead to this machine is damaged, it
must be replaced by WMF Customer Service or a similarly qualified specialist. If the machine is
permanently connected on site, an all-pole circuit breaker (main switch) to EN 60947 with not less than
3 mm contact opening should be fitted ahead of the machine. In the case of a flexible connection, the circuit
breaker is recommended. The power lead must not be allowed to come into contact with hot components.
The main switch and socket are part of the customer’s system. The machine must not be installed with a
fixed site connection if used with a trolley (mobile station).