Phau Ntawv Qhia

µ
WMF coffeemachines
WMF espresso planning information
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water and drainage connections at the customer‘s
premises is to be arranged by the machine owner / operator. The work must be carried out
by authorised installation technicians in compliance with general, country-specific and local regulations.
The WMF service engineers may only connect the coffee machine to existing prepared
connection points. WMF Service is neither authorised nor responsible for carrying out any on-site
installation work prior to connection.
Dimensions
and weight
empty
Width
Height
Depth
Clearance
heights
Weight empty
723 mm
580 mm
540 mm (594 mm with the cup storage slid open)
140 mm Single spout
135 mm Double spout
214 mm Hot water outlet
Approx. 75 kg
Water
supply
Water supply
line
Inlet
temperature
Water drain
tube
TW15 (DN 15 at least DN 6 or 1/4“) hose connector with main shutoff
valve and contaminant filter, with a mesh size of 0.08 mm, by customers
on-site. At least 0.05 MPa (0.5 bar) supply pressure at 2 l/min (low
pressure). At least 0.30 MPa (3.0 bar) supply pressure at 2 l/min
(standard). Maximum 0.6 MPa (6 bar).
Maximum 35 °C.
Tube a minimum of DN 19, minimum downward slope
of 2 cm/m
For use at
altitude
above NN
<2000 m
Electrical
data
Nominal power
rating
6.0-7.0 kW
Power supply 380415 V 50 / 60 Hz (3 / N / PE)
Degree of
protection
IP X0
Protection Class A
Installation
Clearance
For operating, service, and safety reasons the machine should be installed with a clearance
from the building or non-WMF components of not less than 50 mm at the sides and 60 mm
at the back. A minimum working space of 800 mm in front of the coffee machine is
recommended. Clearance of at least 200 mm above the product hopper is recommended. The
height of the installation surface above the floor is at least 850 mm. If the coffee machine
connections are to be run downwards through the counter, please make space for the lines,
which can reduce the usable space below the machine.
If the coffee machine is operated with a water filter the additional space under the machine
depending on the fitler size has to be considered. For further information see filter
instructions.