Instruction Manual

µ
WMF coffeemachines
WMF 9000 F (external storage) planning information
Dimensions
and empty
weight
Width
Height
Depth
Clearance heights
Weight
450 mm
782 mm (with 4 mm feet, without lock)
605 mm (640 mm)
165 mm (206 mm removed spout)
Approx. 65 kg
Water supply Water supply line
Inlet temperature
Onsite:
1/2 inch (TW12) hose connector with main shutoff valve and dirt
filter with 250 sq.m mesh size, on-site. At least 0.36 MPa (3.6 bar)
flow pressure at 6 l/min
1
)
2
)
3
)
Machine site:
Boiler feed ½ inch (TW12)
Rinsing line 3/8 inch (TW8)
At least 0.2 MPa (2 bar) flow pressure at 6 l/min. Maximum 0.6
MPa (6 bar).
Maximum 35 °C.
Water drain
tube (optional)
Hose a minimum of DN 40, minimum downward slope of 2 cm/m.
If coffee machine is installed without grounds separator a 20 mm
fall height is necessary. The fall height can be realised by using
352.389.08.1 from company Geberit or similar.
Calibration
pressure
Boiler 0.32MPa (3.2 bar)
Use at
elevation
above sea level
<2000m
Electrical data Nominal power rating 8.4 14.7 kW
Power supply 380 - 415V
50 / 60 Hz (3 / N / PE)
Degree of protection IP X0
Protection Class I
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water and drainage connections at the customer‘s premises
is to be arranged by the machine owner / operator. The work must be carried out by authorised installation
technicians in compliance with general, country-specific and local regulations. The WMF service engineers may
only connect the coffee machine to existing prepared connection points. WMF Service is neither authorised nor
responsible for carrying out any on-site installation work prior to connection.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF GmbH | WMF Platz 1 | 73312 Geislingen (Steige)
1) Under reconsideration of usual pressure loss caused by water connection set and water filter and to ensure
max. hourly output at necessary machine side supply pressure of 0.2 Mpa (2bar) at 6 l/min
2) Note: For effective operation of the setting routine of the pressure reducer, the system pressure at the
machine connection needs to be at least 2,4bar at 6l/min. If the pressure is lower, the pressure difference
might not be sufficient to set the pressure reducer according to the setting value
3) Note: pressure loss caused by an upstream water filter. Further information can be found in the filter user
manual